XH536E2S11
LX SERIES
275 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 275 / 275 |
| EER2 · BTU/Wh | 10–12 | 275 / 275 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 275 / 275 |
| Cooling capacity · BTU/h | 32,400–35,000 | 275 / 275 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,800 | 275 / 275 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 275 / 275 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 275 / 275 |
| COP at 5°F / −15°C | 2–2.44 | 275 / 275 |
| Equipment / loop type | HP - Split System | 275 / 275 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 275 / 275 |
| Compressor staging | Two-stage | 275 / 275 |
| Connected capability | No | 275 / 275 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217444924 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4045063 → |
CTF48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217444926 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4045064 → |
CTU48C5XFS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 217444927 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4045065 → |
CTM48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217444925 | 16.00 | 8.10 | 17900 | 2.40 | EPA 4045066 → |
CTF48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217444928 | 16.00 | 8.10 | 18100 | 2.38 | EPA 4045067 → |
CTU48C5XFS1+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 217444929 | 16.00 | 8.10 | 18100 | 2.38 | EPA 4045069 → |
CTU48C5XFS2+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 218519343 | 16.00 | 8.10 | 18100 | 2.38 | EPA 4642787 → |
CTF48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218519339 | 16.00 | 8.10 | 18100 | 2.38 | EPA 4642791 → |
CTU48C5XFS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 218519335 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4642795 → |
CTF48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218519331 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4642799 → |
CTM48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218518925 | 16.00 | 8.10 | 17900 | 2.40 | EPA 4643035 → |
CTM48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218518921 | 16.00 | 8.10 | 18000 | 2.40 | EPA 4643039 → |
CTM48C5CFS1+JMVT17CC2N1AHRI reference: 214425643 | 15.20 | 8.10 | 17500 | 2.44 | EPA 3558348 → |
CTM48C5CFS1+JMVT16CC2N1AHRI reference: 214425653 | 15.20 | 8.10 | 17500 | 2.42 | EPA 3558353 → |
CTF48C5CFS1+JMVT17CC2N1AHRI reference: 214425663 | 15.20 | 8.10 | 17200 | 2.00 | EPA 3558358 → |
CTF48C5CFS1+JMVT16CC2N1AHRI reference: 214425673 | 15.20 | 8.10 | 17500 | 2.00 | EPA 3558363 → |
CTF36C5CDS1+JMVT16CC2N1AHRI reference: 214427410 | 15.20 | 8.10 | 17400 | 2.00 | EPA 3558562 → |
JHE42C5CF2SS1AHRI reference: 214425624 | 15.20 | 8.10 | 17300 | 2.00 | EPA 3558807 → |
JHC42C5CF2SS1AHRI reference: 214425634 | 15.20 | 8.10 | 17500 | 2.00 | EPA 3558812 → |
CTM36C5CDS1+JMC16C2SN1AHRI reference: 214431899 | 15.20 | 8.10 | 17600 | 2.44 | EPA 3558818 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →