Luxaire / AIR-SOURCE HEAT PUMP

XH518E2S11

LX SERIES · source records, page 3

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity17,000–18,600BTU/h

Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16249 / 249
EER2 · BTU/Wh12–12.5249 / 249
HSPF2 · BTU/Wh7.8249 / 249
Cooling capacity · BTU/h17,000–18,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300249 / 249
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100249 / 249
COP at 5°F / −15°C2.26–2.34249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU24A5XBS1+TXV+ furnace: TMLV060A12MP12AHRI reference: 21582055515.207.8089002.26EPA 3712614 →
CTU24A5XBS1+TXV+ furnace: TPLC060A12MP13AHRI reference: 21582056015.207.8089002.26EPA 3712619 →
CTU24A5XBS1+TXV+ furnace: LPLC060A12MP13AHRI reference: 21582056515.207.8089002.26EPA 3712624 →
CTF24B5ABS1+ furnace: Z9ET080B12SMPS1AHRI reference: 21582058215.207.8090002.28EPA 3712625 →
CTF30B5ACS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21582095215.207.8088002.30EPA 3712668 →
CTU30B5XCS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21582095715.207.8088002.30EPA 3712673 →
CTM30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21582046815.207.8088002.30EPA 3712677 →
CTF30B5ACS1+ furnace: TL9E060B12UH11AHRI reference: 21582047315.207.8091002.26EPA 3712682 →
CTU30B5XCS1+TXV+ furnace: TL9E060B12UH11AHRI reference: 21582047815.207.8091002.26EPA 3712688 →
CTM30B5ACS1+ furnace: TM8E100B12MP11AHRI reference: 21582048815.207.8091002.28EPA 3712692 →
CTM30B5ACS1+ furnace: TMLE100B12MP11AHRI reference: 21582049315.207.8091002.28EPA 3712697 →
CTF30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21582049815.207.8088002.30EPA 3712702 →
CTU30B5XCS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21582050315.207.8088002.30EPA 3712708 →
CTM24A5ABS1+ furnace: Z8ET060A12LMPS1AHRI reference: 21582097715.207.8088002.26EPA 3712712 →
CTF24A5ABS1+ furnace: Z8ES040A12SMPS1AHRI reference: 21582098715.207.8088002.28EPA 3712717 →
CTU24A5XBS1+TXV+ furnace: Z8ES040A12SMPS1AHRI reference: 21582099215.207.8088002.28EPA 3712723 →
CTF24B5ABS1+ furnace: TMLE080B12MP11AHRI reference: 21582044815.207.8091002.26EPA 3712727 →
CTM24A5ABS1+ furnace: Z8ES060A12SMPS1AHRI reference: 21582052315.207.8090002.28EPA 3712732 →
CTF24A5ABS1+ furnace: TM8V060A12MP12AHRI reference: 21582053315.207.8089002.26EPA 3712737 →
CTF30B5ACS1+ furnace: TM8E080B12MP11AHRI reference: 21582018115.207.8088002.28EPA 3712752 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →