Luxaire / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 3

191 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16191 / 191
EER2 · BTU/Wh11–12191 / 191
HSPF2 · BTU/Wh7.8–8.1191 / 191
Cooling capacity · BTU/h53,000–57,000191 / 191
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500191 / 191
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000191 / 191
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800191 / 191
COP at 5°F / −15°C2–2.46191 / 191
Equipment / loop typeHP - Split System191 / 191
Refrigerant / source-reported GWPR-410A (GWP:2088)191 / 191
Compressor stagingTwo-stage191 / 191
Connected capabilityNo191 / 191

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60JXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21241518815.208.10314002.40EPA 2483474 →
XAHD60JBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21241520315.208.10312002.36EPA 2483477 →
XAFD60JBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241519315.208.10314002.40EPA 2483481 →
XAHD60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241458415.207.80326002.34EPA 2483737 →
XAHD60JBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241500315.208.10312002.36EPA 2483746 →
XAHD60HBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247869515.207.80326002.34EPA 2483846 →
XAHD60JBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21241496315.208.10312002.36EPA 2484030 →
XAHD60JBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241524315.208.10312002.36EPA 2484370 →
XAFD60JBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21248002815.208.10314002.40EPA 2484426 →
XAHD60JXXN1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21241523815.208.10312002.36EPA 2484642 →
XAFD60JXXN1+TXV+ furnace: Z8ES080C16SMPS1AHRI reference: 21241525815.208.10314002.42EPA 2484643 →
XAFD60JBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241526315.208.10314002.42EPA 2484646 →
XAHD60JXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21248102415.208.10312002.36EPA 2484707 →
XAHD60JBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248103115.208.10312002.36EPA 2484711 →
XAHD60JXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21248103815.208.10312002.36EPA 2484719 →
XAHD60JBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248104515.208.10312002.36EPA 2484724 →
XAFD60JXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 21248177115.208.10314002.42EPA 2484733 →
XAFD60JBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248177815.208.10314002.42EPA 2484736 →
XAHD60JXXN1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21248174315.208.10310002.38EPA 2484745 →
XAHD60HBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21241451415.207.80326002.34EPA 2484900 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →