THF2B60T21
LX SERIES
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 191 / 191 |
| EER2 · BTU/Wh | 11–12 | 191 / 191 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 191 / 191 |
| Cooling capacity · BTU/h | 53,000–57,000 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 54,500–59,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–39,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,200–32,800 | 191 / 191 |
| COP at 5°F / −15°C | 2–2.46 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 191 / 191 |
| Compressor staging | Two-stage | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60JBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 212414983 | 16.00 | 8.10 | 31200 | 2.36 | EPA 2483185 → |
XAFD60HXXN1+JMVT20DC2N1+TXVAHRI reference: 210351866 | 16.00 | 8.10 | 30800 | 2.22 | EPA 2786628 → |
XAFD60HXXN1+JMET18DS2N1+TXVAHRI reference: 210358461 | 16.00 | 8.10 | 30800 | 2.26 | EPA 2788235 → |
XAFD60JXXN1+JMVT20DC2N1+TXVAHRI reference: 210353430 | 16.00 | 8.10 | 30800 | 2.26 | EPA 2788690 → |
XAFD60JXXN1+JMET18DS2N1+TXVAHRI reference: 210361845 | 16.00 | 8.10 | 30600 | 2.22 | EPA 2814286 → |
JHVTD60JBCC2N1AHRI reference: 210353438 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3557930 → |
JHVTD60HBCC2N1AHRI reference: 210361169 | 16.00 | 8.10 | 30600 | 2.28 | EPA 3558024 → |
JHETD60HBCS2N1AHRI reference: 210361173 | 16.00 | 8.10 | 30600 | 2.26 | EPA 3558028 → |
JHETD60JBCS2N1AHRI reference: 210361857 | 16.00 | 8.10 | 30800 | 2.24 | EPA 3558032 → |
XAFD60HBCN1+JMVT20DC2N1AHRI reference: 210351870 | 16.00 | 8.10 | 30800 | 2.22 | EPA 3985598 → |
XAFD60HBCN1+JMET18DS2N1AHRI reference: 210358467 | 16.00 | 8.10 | 30800 | 2.26 | EPA 3986727 → |
XAFD60JBCN1+JMVT20DC2N1AHRI reference: 210353434 | 16.00 | 8.10 | 30800 | 2.26 | EPA 3987859 → |
XAFD60JBCN1+JMET18DS2N1AHRI reference: 210361851 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3988447 → |
XAHD60JXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 212415178 | 15.20 | 8.10 | 31000 | 2.38 | EPA 2476358 → |
XAHD60JXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 212481757 | 15.20 | 8.10 | 31200 | 2.36 | EPA 2476456 → |
XAHC60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 212414434 | 15.20 | 7.80 | 32800 | 2.34 | EPA 2477000 → |
XAHD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 212481764 | 15.20 | 8.10 | 31200 | 2.36 | EPA 2477218 → |
XAHD60JXXN1+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 212415218 | 15.20 | 8.10 | 31200 | 2.36 | EPA 2478788 → |
XAFD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212484965 | 15.20 | 8.10 | 31400 | 2.40 | EPA 2478802 → |
XAHD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212481750 | 15.20 | 8.10 | 31000 | 2.38 | EPA 2479132 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →