THF2B48T21
LX SERIES · source records, page 15
390 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 390 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 390 / 390 |
| EER2 · BTU/Wh | 11–12 | 390 / 390 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 390 / 390 |
| Cooling capacity · BTU/h | 44,500–47,500 | 390 / 390 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–47,500 | 390 / 390 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,200 | 390 / 390 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,400–29,800 | 390 / 390 |
| COP at 5°F / −15°C | 2.22–2.84 | 390 / 390 |
| Equipment / loop type | HP - Split System | 390 / 390 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 390 / 390 |
| Compressor staging | Two-stage | 390 / 390 |
| Connected capability | No | 390 / 390 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60HBCN1+ furnace: TL9E080C16UH11AHRI reference: 210345892 | 15.20 | 7.80 | 25000 | 2.46 | EPA 3985834 → |
XAHD60GBCN1+ furnace: TM9E120D20MP12AHRI reference: 210345065 | 15.20 | 7.80 | 24400 | 2.22 | EPA 3986093 → |
XAHC60GBCN1+ furnace: TM9E100C20MP12AHRI reference: 210345077 | 15.20 | 7.80 | 24000 | 2.26 | EPA 3986102 → |
XAHC60GBCN1+ furnace: TM9V100C20MP12AHRI reference: 210344199 | 15.20 | 7.80 | 23800 | 2.26 | EPA 3986256 → |
XAHC60GBCN1+ furnace: TP9C100C20MP13AHRI reference: 210344203 | 15.20 | 7.80 | 23800 | 2.26 | EPA 3986257 → |
XAHC60GBCN1+ furnace: LP9C100C20MP13AHRI reference: 210344207 | 15.20 | 7.80 | 23800 | 2.26 | EPA 3986265 → |
XAHD60GBCN1+ furnace: TM9E100C20MP12AHRI reference: 210344295 | 15.20 | 7.80 | 24000 | 2.24 | EPA 3986272 → |
XAHD60GBCN1+ furnace: TM9E080C20MP12AHRI reference: 210344337 | 15.20 | 7.80 | 24000 | 2.24 | EPA 3986276 → |
XAFC60HBCN1+ furnace: TL8E080C16UH11AHRI reference: 210348778 | 15.20 | 7.80 | 23400 | 2.28 | EPA 3986384 → |
XAFC60HBCN1+JMVT17CC2N1AHRI reference: 210348786 | 15.20 | 8.10 | 23800 | 2.28 | EPA 3986391 → |
XAFC60HBCN1+ furnace: TL9E100C20UH11AHRI reference: 210358007 | 15.20 | 8.10 | 23800 | 2.28 | EPA 3986640 → |
XAHD60HBCN1+ furnace: TL8E080C16UH11AHRI reference: 210358023 | 15.20 | 8.10 | 25000 | 2.48 | EPA 3986659 → |
XAFD60HBCN1+JMVT20DC2N1AHRI reference: 210358039 | 15.20 | 8.10 | 23800 | 2.30 | EPA 3986672 → |
XAHC60GBCN1+ furnace: TL9E100C20UH11AHRI reference: 210348370 | 15.20 | 7.80 | 24000 | 2.26 | EPA 3986814 → |
XAHD60GBCN1+ furnace: TL8E100C20UH11AHRI reference: 210348386 | 15.20 | 7.80 | 24000 | 2.24 | EPA 3986826 → |
XAFC60GBCN1+JMVT16CC2N1AHRI reference: 210348426 | 15.20 | 8.10 | 25400 | 2.44 | EPA 3986839 → |
XAFC60HBCN1+ furnace: TM9Y100C16MP11AHRI reference: 210348506 | 15.20 | 7.80 | 23800 | 2.28 | EPA 3986862 → |
XAFC60HBCN1+ furnace: TM9V100C16MP12AHRI reference: 210348554 | 15.20 | 7.80 | 23400 | 2.28 | EPA 3986893 → |
XAFC60HBCN1+ furnace: TP9C100C16MP13AHRI reference: 210348558 | 15.20 | 7.80 | 23400 | 2.28 | EPA 3986898 → |
XAFC60HBCN1+ furnace: LP9C100C16MP13AHRI reference: 210348562 | 15.20 | 7.80 | 23400 | 2.28 | EPA 3986899 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.