Luxaire / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 5

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16461 / 461
EER2 · BTU/Wh11.7–12461 / 461
HSPF2 · BTU/Wh7.8–8.1461 / 461
Cooling capacity · BTU/h39,500–42,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600461 / 461
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600461 / 461
COP at 5°F / −15°C1.98–2.42461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-410A (GWP:2088)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC48FXXN1+TXV+ furnace: TL9E100C20UH11AHRI reference: 21034707116.008.10204002.12EPA 2787488
XAHC48FXXN1+JMET16CS2N1+TXVAHRI reference: 21034713116.008.10210002.20EPA 2787496
XAHC60GBCN1+JMVT17CC2N1AHRI reference: 21327129316.008.10216002.40EPA 2840070
XAFD60GBCN1+JMET18DS4N1AHRI reference: 21327130416.008.10212002.32EPA 2840083
XAHC60GBCN1+JMET12CS4N1AHRI reference: 21327132516.008.10218002.38EPA 2840102
XAFD60GXXN1+JMET18DS4N1+TXVAHRI reference: 21327104316.008.10212002.32EPA 2840181
XAFD60GBCN1+JMET18DS2N1AHRI reference: 21327105016.008.10212002.34EPA 2840189
JHETD48GBCS2N1AHRI reference: 21327107716.008.10208002.32EPA 2840201
XAFD60GXXN1+JMVT20DC2N1+TXVAHRI reference: 21327108116.008.10206002.34EPA 2840212
XAHC60GBCN1+JMET12CS2N1AHRI reference: 21327107116.008.10216002.38EPA 2840217
XAFC60GBCN1+JMVT17CC2N1AHRI reference: 21327108616.008.10208002.32EPA 2840225
XAFD60GXXN1+JMET18DS2N1+TXVAHRI reference: 21327110016.008.10212002.34EPA 2840239
XAFC60GBCN1+JMET16CS4N1AHRI reference: 21327110716.008.10212002.32EPA 2840246
XAFD60GBCN1+JMVT20DC2N1AHRI reference: 21327113316.008.10206002.34EPA 2840272
XAHD60GBCN1+JMET18DS2N1AHRI reference: 21327115016.008.10220002.40EPA 2840291
XAFC60GBCN1+JMET16CS2N1AHRI reference: 21327116416.008.10216002.30EPA 2840302
XAHC60GBCN1+JMET16CS4N1AHRI reference: 21327120816.008.10220002.40EPA 2840345
XAHC60GBCN1+JMVT16CC2N1AHRI reference: 21327124416.008.10216002.40EPA 2840383
XAHC60GBCN1+JMET16CS2N1AHRI reference: 21327126616.008.10222002.38EPA 2840404
XAFC60GBCN1+JMET12CS2N1AHRI reference: 21327128016.008.10208002.30EPA 2840420

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →