Luxaire / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 16

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16461 / 461
EER2 · BTU/Wh11.7–12461 / 461
HSPF2 · BTU/Wh7.8–8.1461 / 461
Cooling capacity · BTU/h39,500–42,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600461 / 461
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600461 / 461
COP at 5°F / −15°C1.98–2.42461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-410A (GWP:2088)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+JMC20D2SN1AHRI reference: 21479973515.208.10222002.40EPA 3559779 →
XAFC60GBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21259418315.207.80202002.22EPA 3560556 →
XAHC60GBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21259467815.208.10216002.34EPA 3560561 →
XAUC48FXXN1+TXV+ furnace: TL8E080C16UH11AHRI reference: 21034710315.208.10193002.02EPA 3720628 →
XAUC48FXXN1+TXV+ furnace: TP9C100C16MP13AHRI reference: 21034773215.208.10195002.06EPA 3721272 →
XAUC48FXXN1+TXV+ furnace: TM9V100C16MP12AHRI reference: 21034772415.208.10195002.06EPA 3721493 →
XAUC48FXXN1+TXV+ furnace: TM9Y080C16MP11AHRI reference: 21034769215.207.80196002.00EPA 3721501 →
XAHC48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21034376315.208.10184002.02EPA 3984573 →
XAFC48FXXN1+TXV+ furnace: TM9Y100C16MP11AHRI reference: 21034376915.207.80196002.02EPA 3984578 →
XAFC48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21034377515.207.80196002.02EPA 3984580 →
XAHC48FBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21034379315.208.10186002.04EPA 3984585 →
XAHD48FBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21034767415.208.10202002.08EPA 3984908 →
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11AHRI reference: 21034768015.207.80196002.00EPA 3984913 →
XAFC48FBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21034768615.207.80196002.00EPA 3984917 →
XAHC48FBCN1+ furnace: TM9Y060B12MP11AHRI reference: 21034770415.207.80192002.00EPA 3984919 →
XAFC48FXXN1+TXV+ furnace: TM9V100C16MP12AHRI reference: 21034771015.208.10195002.06EPA 3984926 →
XAFC48FXXN1+TXV+ furnace: TP9C100C16MP13AHRI reference: 21034771415.208.10195002.06EPA 3984928 →
XAHC48FBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21034665915.208.10202002.08EPA 3984943 →
XAFD48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21034667115.207.80196002.02EPA 3984948 →
XAHD48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21034672715.208.10193002.06EPA 3984970 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →