SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity33,400–36,000BTU/h

Each efficiency range summarizes published EPA records for THF2B36T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 225 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16225 / 225
EER2 · BTU/Wh11.7–12225 / 225
HSPF2 · BTU/Wh7.8–8.1225 / 225
Cooling capacity · BTU/h33,400–36,000225 / 225
Heating capacity at 47°F / 8.3°C · BTU/h32,600–34,800225 / 225
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800225 / 225
Heating capacity at 5°F / −15°C · BTU/h16,500–20,000225 / 225
COP at 5°F / −15°C1.96–2.44225 / 225
Equipment / loop typeHP - Split System225 / 225
Refrigerant / source-reported GWPR-410A (GWP:2088)225 / 225
Compressor stagingTwo-stage225 / 225
Connected capabilityNo225 / 225

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC36DBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21248552115.207.80181002.18EPA 2481101
XAHC36DBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248552615.207.80181002.18EPA 2481187
XAHB36DBCN1+ furnace: Z8ES040A12SMPS1AHRI reference: 21247551215.207.80180002.16EPA 2482346
XAFC36DBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21248849115.207.80184002.16EPA 2482517
XAFC36DBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248849615.207.80184002.16EPA 2482525
XAHC36DBCN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21247541615.207.80181002.16EPA 2482715
XAHC36DBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21247807015.207.80177002.16EPA 2483283
XAFC48FBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21247561015.208.10182002.16EPA 2484444
XAHB36DBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248619415.207.80180002.14EPA 2485682
XAFC48FXXN1+JMVT17CC2N1+TXVAHRI reference: 21034357315.208.10175002.06EPA 3624813
XAFB36DXXN1+JMVT12BC2N1+TXVAHRI reference: 21035116415.207.80168001.98EPA 3624849
XAFB36DXXN1+JMET12BS2N1+TXVAHRI reference: 21035608015.207.80166001.98EPA 3624871
XAFC48FXXN1+JMET12CS2N1+TXVAHRI reference: 21035444115.208.10176002.04EPA 3624897
XAFC48FXXN1+JMET16CS2N1+TXVAHRI reference: 21034359715.208.10173002.06EPA 3624917
XAFC48FXXN1+JMVT16CC2N1+TXVAHRI reference: 21035138815.208.10175002.06EPA 3624945
JHETC36DBCS2N1AHRI reference: 21033651915.207.80200002.44EPA 3984239
XAHC48FBCN1+ furnace: TM8V080B12MP12AHRI reference: 21034349015.207.80175002.04EPA 3984491
XAFC48FBCN1+JMVT17CC2N1AHRI reference: 21034357715.208.10175002.06EPA 3984510
XAFC48FBCN1+JMET16CS2N1AHRI reference: 21034360315.208.10173002.06EPA 3984533
XAHC36DBCN1+ furnace: TL8E080C16UH11AHRI reference: 21035186215.207.80174002.06EPA 3985593

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.