Heating performance & equipment details
Ranges include the 884 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 884 / 884 |
| EER2 · BTU/Wh | 9–10.5 | 884 / 884 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 884 / 884 |
| Cooling capacity · BTU/h | 31,400–35,200 | 884 / 884 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 884 / 884 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 884 / 884 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 884 / 884 |
| COP at 5°F / −15°C | 1.8–2.18 | 884 / 884 |
| Equipment / loop type | HP - Split System | 884 / 884 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 884 / 884 |
| Compressor staging | Continuously variable | 884 / 884 |
| Connected capability | No | 884 / 884 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHB36DXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211390863 | 16.50 | 8.10 | 23800 | 2.02 | EPA 2480434 → |
XAHC48FXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211397378 | 16.50 | 8.50 | 23800 | 2.06 | EPA 2480574 → |
XAFC48FBCN1+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 211395696 | 16.50 | 8.50 | 24000 | 2.06 | EPA 2480673 → |
XAFD48FBCN1+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 211395280 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480741 → |
XAFC48FXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211395290 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480744 → |
XAFD48FBCN1+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211395234 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480746 → |
XAFD48FXXN1+TXV+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 211395224 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480748 → |
XAFC48FXXN1+TXV+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 211395600 | 16.50 | 8.50 | 24000 | 2.06 | EPA 2480756 → |
XAHC36DBCN1+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 211392985 | 16.50 | 8.10 | 24600 | 2.08 | EPA 2480757 → |
XAFD48FXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211395201 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480801 → |
XAFC48FXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211395554 | 16.50 | 8.50 | 24000 | 2.06 | EPA 2480804 → |
XAFC48FXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211395576 | 16.50 | 8.50 | 24000 | 2.06 | EPA 2480806 → |
XAFC48FBCN1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211395607 | 16.50 | 8.50 | 24000 | 2.06 | EPA 2480813 → |
XAFD48FBCN1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211395255 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480816 → |
XAFD48FXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211395175 | 16.50 | 8.50 | 23600 | 2.06 | EPA 2480849 → |
XAHC48FBCN1+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 211395165 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2480865 → |
XAHC48FBCN1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211395143 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2480871 → |
XAHC48FXXN1+TXV+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 211395109 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2480875 → |
XAHC48FXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211395088 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2480912 → |
XAHC48FXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211395070 | 16.50 | 8.50 | 23200 | 2.02 | EPA 2480933 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →