HMH72B341
HMH7 · source records, page 3
884 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 884 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 884 / 884 |
| EER2 · BTU/Wh | 9–10.5 | 884 / 884 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 884 / 884 |
| Cooling capacity · BTU/h | 31,400–35,200 | 884 / 884 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 884 / 884 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 884 / 884 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 884 / 884 |
| COP at 5°F / −15°C | 1.8–2.18 | 884 / 884 |
| Equipment / loop type | HP - Split System | 884 / 884 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 884 / 884 |
| Compressor staging | Continuously variable | 884 / 884 |
| Connected capability | No | 884 / 884 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC36DXXN1+JMET12CS2N1+TXVCold climate designationAHRI reference: 213297849 | 18.50 | 8.50 | 24200 | 2.14 | EPA 4598634 → |
XAFC36DXXN1+TXV+ furnace: Z9ET100C16SMPS1Cold climate designationAHRI reference: 213297679 | 18.50 | 8.50 | 24400 | 2.06 | EPA 4598714 → |
XAFC36DXXN1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 213297509 | 18.50 | 8.10 | 24000 | 2.08 | EPA 4598761 → |
XAFC30CXXN1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 213297319 | 18.50 | 8.50 | 23400 | 2.04 | EPA 4598850 → |
XAFC36DXXN1+TXV+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 213297309 | 18.50 | 8.50 | 24200 | 2.14 | EPA 4598855 → |
XAFB30CXXN1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 213297099 | 18.50 | 8.10 | 23400 | 2.04 | EPA 4598926 → |
XAHC36DXXN1+TXV+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 213297079 | 18.50 | 8.50 | 24000 | 2.10 | EPA 4598932 → |
XAFB30CXXN1+TXV+ furnace: Z9ES060A10SMPS1Cold climate designationAHRI reference: 213297059 | 18.50 | 8.10 | 23200 | 2.02 | EPA 4598938 → |
XAFC36DBCN1+ furnace: Z8ES100B12LMPS1Cold climate designationAHRI reference: 213296929 | 18.50 | 8.10 | 24600 | 2.12 | EPA 4598988 → |
XAFC36DXXN1+TXV+ furnace: Z8ES100B12LMPS1Cold climate designationAHRI reference: 213296919 | 18.50 | 8.10 | 24600 | 2.12 | EPA 4598993 → |
XAFC36DXXN1+TXV+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 213296914 | 18.50 | 8.10 | 24600 | 2.12 | EPA 4598998 → |
XAFB30CXXN1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 213296794 | 18.50 | 8.10 | 23400 | 2.02 | EPA 4599060 → |
XAFB36DBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211391847 | 18.00 | 8.10 | 23800 | 2.06 | EPA 2474071 → |
XAFB36DXXN1+TXV+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211391832 | 18.00 | 8.10 | 23800 | 2.06 | EPA 2474108 → |
XAFC36DBCN1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211392337 | 18.00 | 8.10 | 24400 | 2.06 | EPA 2474242 → |
XAFC36DXXN1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 211388613 | 18.00 | 8.10 | 23800 | 2.08 | EPA 2474513 → |
XAFC36DBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211392322 | 18.00 | 8.10 | 24400 | 2.06 | EPA 2474604 → |
XAHC36DBCN1+ furnace: TM8Y080C16MP11Cold climate designationAHRI reference: 211389482 | 18.00 | 8.10 | 24400 | 2.06 | EPA 2474779 → |
XAFB36DXXN1+TXV+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211392396 | 18.00 | 8.10 | 24400 | 2.06 | EPA 2474934 → |
XAFB36DBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211392411 | 18.00 | 8.10 | 24400 | 2.06 | EPA 2474939 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →