HMH72B341
HMH7 · source records, page 28
884 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 884 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 884 / 884 |
| EER2 · BTU/Wh | 9–10.5 | 884 / 884 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 884 / 884 |
| Cooling capacity · BTU/h | 31,400–35,200 | 884 / 884 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 884 / 884 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 884 / 884 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 884 / 884 |
| COP at 5°F / −15°C | 1.8–2.18 | 884 / 884 |
| Equipment / loop type | HP - Split System | 884 / 884 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 884 / 884 |
| Compressor staging | Continuously variable | 884 / 884 |
| Connected capability | No | 884 / 884 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC30CXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388283 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598325 → |
XAFC30CXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388269 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598330 → |
XAFB30CXXN1+TXV+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 211387995 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598356 → |
XAFB30CXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387981 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598361 → |
XAFB30CXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387968 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598366 → |
XAFC30CXXN1+TXV+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 211387868 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598368 → |
XAFC30CXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387854 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598373 → |
XAFC30CXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387841 | 17.00 | 8.10 | 23600 | 2.02 | EPA 4598378 → |
XAFC30CXXN1+TXV+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 211387678 | 17.00 | 8.10 | 23400 | 2.04 | EPA 4598404 → |
XAFC30CXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211387670 | 17.00 | 8.10 | 23400 | 2.04 | EPA 4598409 → |
XAFC30CXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211387661 | 17.00 | 8.10 | 23400 | 2.04 | EPA 4598414 → |
XAHC30CXXN1+TXV+ furnace: LP9C100C16MP13Cold climate designationAHRI reference: 211387493 | 17.00 | 8.10 | 23000 | 2.00 | EPA 4598430 → |
XAHC30CXXN1+TXV+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 211387480 | 17.00 | 8.10 | 23000 | 2.00 | EPA 4598435 → |
XAHC30CXXN1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 211393429 | 17.00 | 8.10 | 23000 | 2.00 | EPA 4598467 → |
XAHC30CXXN1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 211393169 | 17.00 | 8.10 | 23200 | 1.96 | EPA 4598489 → |
XAFC30CXXN1+TXV+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 211393124 | 17.00 | 8.50 | 23200 | 2.04 | EPA 4598494 → |
XAHC30CXXN1+TXV+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 211393079 | 17.00 | 8.10 | 23200 | 2.00 | EPA 4598499 → |
XAFC30CXXN1+TXV+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 211393045 | 17.00 | 8.50 | 23400 | 2.06 | EPA 4598504 → |
XAHB30CXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211390951 | 17.00 | 8.10 | 23000 | 1.98 | EPA 4598514 → |
XAFB30CXXN1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 211390797 | 17.00 | 8.10 | 23600 | 2.00 | EPA 4598519 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →