HMH72B341
HMH7 · source records, page 21
884 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 884 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 884 / 884 |
| EER2 · BTU/Wh | 9–10.5 | 884 / 884 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 884 / 884 |
| Cooling capacity · BTU/h | 31,400–35,200 | 884 / 884 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 884 / 884 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 884 / 884 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 884 / 884 |
| COP at 5°F / −15°C | 1.8–2.18 | 884 / 884 |
| Equipment / loop type | HP - Split System | 884 / 884 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 884 / 884 |
| Compressor staging | Continuously variable | 884 / 884 |
| Connected capability | No | 884 / 884 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHB36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388134 | 17.00 | 8.10 | 23400 | 1.98 | EPA 2477661 → |
XAHC36DXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 211387690 | 17.00 | 8.10 | 23400 | 2.02 | EPA 2477817 → |
XAFD48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396113 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2477861 → |
XAFD48FBCN1+ furnace: TMLE120C16MP11Cold climate designationAHRI reference: 211398252 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2477912 → |
XAFB36DXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388303 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2477973 → |
XAHC36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387681 | 17.00 | 8.10 | 23400 | 2.02 | EPA 2478000 → |
XAFC48FXXN1+TXV+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211398653 | 17.00 | 8.50 | 23800 | 2.06 | EPA 2478071 → |
XAHC36DBCN1+ furnace: LP9C060B12MP13Cold climate designationAHRI reference: 211388082 | 17.00 | 8.10 | 23800 | 2.00 | EPA 2478102 → |
XAFC48FXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396143 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2478106 → |
XAHC36DXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388747 | 17.00 | 8.10 | 23400 | 2.02 | EPA 2478241 → |
XAHC48FBCN1+ furnace: TMLE100C16MP11Cold climate designationAHRI reference: 211398448 | 17.00 | 8.50 | 23200 | 2.04 | EPA 2478280 → |
XAHC48FBCN1+ furnace: TM8E100C16MP11Cold climate designationAHRI reference: 211398433 | 17.00 | 8.50 | 23200 | 2.04 | EPA 2478291 → |
XAFC48FBCN1+ furnace: TMLE120C16MP11Cold climate designationAHRI reference: 211398324 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2478340 → |
XAFB36DXXN1+TXV+ furnace: LP9C060B12MP13Cold climate designationAHRI reference: 211388332 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2478353 → |
XAFC48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211398294 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2478359 → |
XAHC48FBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211398638 | 17.00 | 8.10 | 23200 | 2.02 | EPA 2478457 → |
XAHC36DBCN1+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388069 | 17.00 | 8.10 | 23800 | 2.00 | EPA 2478484 → |
XAFC48FBCN1+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211396165 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2478513 → |
XAHC36DBCN1+ furnace: LPLC100C16MP13Cold climate designationAHRI reference: 211390070 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2478514 → |
XAHC48FBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211398631 | 17.00 | 8.10 | 23200 | 2.02 | EPA 2478817 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →