Luxaire / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 6

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS2+ furnace: TP9C100C16MP13AHRI reference: 21868958317.508.10338002.20EPA 4677807 →
CTU60C5XGS2+TXV+ furnace: LPLC100C20MP13AHRI reference: 21868958017.508.10340002.20EPA 4677810 →
CTF60C5CGS2+ furnace: LPLC100C20MP13AHRI reference: 21868957917.508.10340002.20EPA 4677811 →
CTM60C5CGS2+ furnace: LPLC120C20MP13AHRI reference: 21868957817.508.10338002.20EPA 4677812 →
CTF60C5CGS2+ furnace: LPLC120C20MP13AHRI reference: 21868957517.508.10340002.20EPA 4677813 →
CTU60C5XGS2+TXV+ furnace: LPLC120C20MP13AHRI reference: 21868957417.508.10340002.20EPA 4677814 →
CTM60C5CGS2+ furnace: TPLC080C16MP13AHRI reference: 21868957117.508.10338002.20EPA 4677817 →
CTM60D5CGS2+ furnace: TP9C120D20MP13AHRI reference: 21868956617.508.10338002.20EPA 4677819 →
CTF60D5CGS2+ furnace: TP9C120D20MP13AHRI reference: 21868956317.508.10338002.20EPA 4677822 →
CTM60C5CGS2+ furnace: TPLC100C20MP13AHRI reference: 21868955717.508.10338002.20EPA 4677824 →
CTM60C5CGS2+ furnace: TPLC100C16MP13AHRI reference: 21868955617.508.10338002.20EPA 4677825 →
CTU60C5XGS2+TXV+ furnace: TPLC120C20MP13AHRI reference: 21868955317.508.10340002.20EPA 4677828 →
CTF60C5CGS2+ furnace: TPLC120C20MP13AHRI reference: 21868955217.508.10340002.20EPA 4677829 →
CTF60C5CGS2+ furnace: TPLC100C20MP13AHRI reference: 21868955117.508.10340002.20EPA 4677830 →
CTU60C5XGS2+TXV+ furnace: TPLC100C20MP13AHRI reference: 21868955017.508.10340002.20EPA 4677831 →
CTM60C5CGS2+ furnace: TPLC120C20MP13AHRI reference: 21868954917.508.10338002.20EPA 4677832 →
CTM60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 21868954617.508.10342002.22EPA 4677833 →
CTF60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 21868954517.508.10344002.20EPA 4677834 →
CTU60C5XGS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 21868954417.508.10344002.20EPA 4677835 →
CTM60C5CGS2+ furnace: TM9V100C16MP12AHRI reference: 21868953917.508.10338002.20EPA 4677836 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →