Luxaire / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 10

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CJS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21869999117.508.10390002.28EPA 4685203 →
CTF60D5CJS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21869998717.508.10390002.28EPA 4685207 →
CTM60C5CGS1+ furnace: LPLC120C20MP13AHRI reference: 21870074517.508.10338002.20EPA 4686169 →
CTM60C5CGS1+ furnace: LPLC100C20MP13AHRI reference: 21870074317.508.10338002.20EPA 4686171 →
CTM60C5CGS1+ furnace: TPLC120C20MP13AHRI reference: 21870073917.508.10338002.20EPA 4686175 →
CTM60C5CGS1+ furnace: TPLC100C20MP13AHRI reference: 21870073517.508.10338002.20EPA 4686179 →
CTM60C5CGS1+ furnace: TMLV120C20MP12AHRI reference: 21870073117.508.10338002.20EPA 4686183 →
CTM60C5CGS1+ furnace: TM8V100C20MP12AHRI reference: 21870072717.508.10338002.20EPA 4686187 →
CTM60C5CGS1+ furnace: TM8V120C20MP12AHRI reference: 21870072317.508.10338002.20EPA 4686191 →
CTM60C5CGS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21870068317.508.10346002.22EPA 4686231 →
CTU60C5XGS1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21870067917.508.10340002.22EPA 4686235 →
CTU60C5XGS1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21870067517.508.10340002.22EPA 4686239 →
CTF60C5CGS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21870067117.508.10340002.22EPA 4686243 →
CTF60C5CGS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21870066717.508.10340002.22EPA 4686247 →
CTM60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21870066317.508.10348002.26EPA 4686251 →
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21870065917.508.10348002.26EPA 4686255 →
CTU60C5XGS1+TXV+ furnace: TM9E080C16MP12AHRI reference: 21870058717.508.10352002.20EPA 4686327 →
CTF60C5CGS1+ furnace: TM9E080C16MP12AHRI reference: 21870058317.508.10352002.20EPA 4686331 →
CTM60C5CGS1+ furnace: LPLC100C16MP13AHRI reference: 21870054517.508.10338002.20EPA 4686369 →
CTM60C5CGS1+ furnace: LPLC080C16MP13AHRI reference: 21870054317.508.10338002.20EPA 4686371 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →