HH860E2S11
LX SERIES · source records, page 29
623 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 623 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 623 / 623 |
| EER2 · BTU/Wh | 10–12 | 623 / 623 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 623 / 623 |
| Cooling capacity · BTU/h | 43,500–54,500 | 623 / 623 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 623 / 623 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 623 / 623 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 623 / 623 |
| COP at 5°F / −15°C | 2 | 623 / 623 |
| Equipment / loop type | HP - Split System | 623 / 623 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 623 / 623 |
| Compressor staging | Continuously variable | 623 / 623 |
| Connected capability | No | 623 / 623 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS1+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214397870 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739042 → |
CTM60C5CGS1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 214398628 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739064 → |
CTF60C5CGS1+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214398237 | 17.00 | 9.00 | 34000 | 2.00 | EPA 3739069 → |
CTM60C5CGS1+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214398677 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739072 → |
CTF60D5CGS1+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214397919 | 17.00 | 9.00 | 35000 | 2.00 | EPA 3739092 → |
CTU60C5XGS1+TXV+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214720170 | 17.00 | 9.00 | 34000 | 2.00 | EPA 3739148 → |
CTU60D5XGS1+TXV+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214649904 | 17.00 | 9.00 | 35000 | 2.00 | EPA 3739152 → |
CTU60C5XGS1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 214720032 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3739173 → |
CTU60C5XGS1+TXV+ furnace: LP9C080C16MP13Cold climate designationAHRI reference: 214720037 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3739179 → |
CTU60C5XGS1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 214720039 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3739180 → |
CTU60C5XGS1+TXV+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 214720155 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740304 → |
CTU60C5XGS1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 214719941 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740329 → |
CTU60C5XGS1+TXV+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214719982 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740337 → |
CTU60C5XGS1+TXV+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214720022 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740343 → |
CTU60D5XGS1+TXV+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374570 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047609 → |
CTM60D5CGS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374611 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047652 → |
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374769 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047793 → |
CTU60C5XGS1+TXV+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 216801817 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047977 → |
CTF60C5CGS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 216801818 | 17.00 | 9.00 | 33400 | 2.00 | EPA 4047978 → |
CTU60C5XGS1+TXV+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 216801819 | 17.00 | 9.00 | 33400 | 2.00 | EPA 4047979 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.