Luxaire / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 9

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5CDS1+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21745503319.008.50234002.00EPA 4048429
CTF36C5CDS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 21745503419.008.50238002.00EPA 4048430
CTM36C5CDS1+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21745503519.008.50234002.00EPA 4048431
CTM36C5CDS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21745503619.009.00232002.00EPA 4048432
JHC36C5CD2SS1Cold climate designationAHRI reference: 21439538919.009.00252002.10EPA 4514613
JHE36C5AD2SS2Cold climate designationAHRI reference: 21845708419.008.50250002.00EPA 4617158
JHE36C5CD2SS2Cold climate designationAHRI reference: 21845708019.008.50250002.00EPA 4617162
CTU48C5XFS2+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21852238119.009.00254002.00EPA 4643215
CTU48C5XFS2+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21852237719.009.00254002.00EPA 4643219
CTF48C5CFS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852237319.009.00254002.00EPA 4643223
CTF48C5CFS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852236919.009.00254002.00EPA 4643227
CTU48C5XFS2+JMC17C2SN1+TXVAHRI reference: 21852236519.009.00252002.00EPA 4643231
CTF48C5CFS2+JMC17C2SN1AHRI reference: 21852236119.009.00252002.00EPA 4643235
CTF48C5AFS2+JMC17C2SN1AHRI reference: 21852235719.009.00252002.00EPA 4643239
CTU48C5XFS2+TXV+ furnace: Z9ES080C16SMPS1AHRI reference: 21852233319.009.00258002.00EPA 4643263
CTF48C5CFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852232919.009.00258002.00EPA 4643267
CTU48C5XFS2+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21852232519.009.00254002.00EPA 4643271
CTU48C5XFS2+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21852232119.009.00254002.00EPA 4643275
CTF48C5CFS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21852231719.009.00254002.00EPA 4643279
CTF48C5CFS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21852231319.009.00254002.00EPA 4643283

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →