Luxaire / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 31

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5ADS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852211318.008.50258002.00EPA 4643463 →
CTF36C5CDS2+ furnace: TL8E080C16UH11AHRI reference: 21852210918.008.50264002.00EPA 4643467 →
CTF36C5ADS2+ furnace: TL8E080C16UH11AHRI reference: 21852210518.008.50264002.00EPA 4643471 →
CTF36C5CDS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852207718.008.50272002.00EPA 4643499 →
CTF36C5ADS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852207318.008.50272002.00EPA 4643503 →
CTF36C5CDS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852206918.008.50250002.00EPA 4643507 →
CTF36C5ADS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852206518.008.50250002.00EPA 4643511 →
CTF36C5CDS2+ furnace: LP9C100C16MP13AHRI reference: 21852206318.008.50256002.00EPA 4643513 →
CTF36C5CDS2+ furnace: TP9C100C16MP13AHRI reference: 21852205918.008.50256002.00EPA 4643517 →
CTF36C5CDS2+ furnace: TM9V100C16MP12AHRI reference: 21852205518.008.50256002.00EPA 4643521 →
CTF36C5ADS2+ furnace: LP9C100C16MP13AHRI reference: 21852205318.008.50256002.00EPA 4643523 →
CTF36C5ADS2+ furnace: TP9C100C16MP13AHRI reference: 21852204918.008.50256002.00EPA 4643527 →
CTF36C5ADS2+ furnace: TM9V100C16MP12AHRI reference: 21852204518.008.50256002.00EPA 4643531 →
CTF36C5CDS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852204118.008.50262002.00EPA 4643535 →
CTF36C5CDS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852203718.008.50262002.00EPA 4643539 →
CTF36C5ADS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852203318.008.50262002.00EPA 4643543 →
CTF36C5ADS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852202918.008.50262002.00EPA 4643547 →
CTF36C5CDS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852202518.008.50254002.00EPA 4643551 →
CTF36C5CDS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852202118.008.50254002.00EPA 4643555 →
CTF36C5ADS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852201718.008.50254002.00EPA 4643559 →