HH836E2S11
LX SERIES · source records, page 29
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36B5CDS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374708 | 18.00 | 8.50 | 24200 | 2.00 | EPA 4047710 → |
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374713 | 18.00 | 8.50 | 24000 | 2.00 | EPA 4047714 → |
CTU36B5XDS1+TXV+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374749 | 18.00 | 8.50 | 24200 | 2.00 | EPA 4047774 → |
CTM36C5CDS1+ furnace: Z9ET080C16SMPS1Cold climate designationAHRI reference: 216374754 | 18.00 | 8.50 | 23600 | 2.00 | EPA 4047778 → |
CTF30A5ADS1+ furnace: TL8E060A12UH11AHRI reference: 216508766 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639537 → |
CTF30A5ADS1+ furnace: TMLE060A12MP11AHRI reference: 216508732 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639542 → |
CTF30A5ADS1+ furnace: TM8E060A12MP11AHRI reference: 216508723 | 18.00 | 8.00 | 25400 | 2.00 | EPA 4639545 → |
CTU48C5XFS2+TXV+ furnace: LP9C100C16MP13AHRI reference: 218522355 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643241 → |
CTU48C5XFS2+TXV+ furnace: TP9C100C16MP13AHRI reference: 218522351 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643245 → |
CTU48C5XFS2+TXV+ furnace: TM9V100C16MP12AHRI reference: 218522347 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643249 → |
CTF48C5CFS2+ furnace: LP9C100C16MP13AHRI reference: 218522345 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643251 → |
CTF48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 218522341 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643255 → |
CTF48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 218522337 | 18.00 | 9.00 | 25200 | 2.00 | EPA 4643259 → |
CTU48C5XFS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 218522293 | 18.00 | 9.00 | 25400 | 2.00 | EPA 4643303 → |
CTF48C5CFS2+ furnace: TL9E080C16UH11AHRI reference: 218522289 | 18.00 | 9.00 | 25400 | 2.00 | EPA 4643307 → |
CTU48C5XFS2+TXV+ furnace: LP9C100C20MP13AHRI reference: 218522287 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643309 → |
CTU48C5XFS2+TXV+ furnace: TP9C100C20MP13AHRI reference: 218522283 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643313 → |
CTU48C5XFS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 218522279 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643317 → |
CTF48C5CFS2+ furnace: LP9C100C20MP13AHRI reference: 218522277 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643319 → |
CTF48C5CFS2+ furnace: TP9C100C20MP13AHRI reference: 218522273 | 18.00 | 9.00 | 25800 | 2.00 | EPA 4643323 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →