Luxaire / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES · source records, page 4

264 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 264 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18264 / 264
EER2 · BTU/Wh11–12264 / 264
HSPF2 · BTU/Wh8.1–8.5264 / 264
Cooling capacity · BTU/h22,400–24,000264 / 264
Heating capacity at 47°F / 8.3°C · BTU/h22,000–24,000264 / 264
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,800264 / 264
Heating capacity at 5°F / −15°C · BTU/h17,200–18,700264 / 264
COP at 5°F / −15°C2.22–2.46264 / 264
Equipment / loop typeHP - Split System264 / 264
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)264 / 264
Compressor stagingTwo-stage264 / 264
Connected capabilityNo264 / 264

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 21864331517.008.50182002.30EPA 4666814 →
CTU30B5XCS2+TXV+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 21864331017.008.50181002.32EPA 4666819 →
CTU30B5XCS2+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21864330317.008.50181002.32EPA 4666826 →
CTF30B5ACS2+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 21864329817.008.50181002.32EPA 4666831 →
CTF30B5ACS2+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21864329217.008.50181002.32EPA 4666837 →
CTM30B5ACS2+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 21864328517.008.50181002.30EPA 4666844 →
CTM30B5ACS2+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 21864328017.008.50181002.30EPA 4666849 →
CTM30B5ACS2+JME12B2SN2Cold climate designationAHRI reference: 21864327417.008.50175002.26EPA 4666855 →
CTU30B5XCS2+JME08B2SN2+TXVAHRI reference: 21864325717.008.10172002.24EPA 4666872 →
CTF30B5ACS2+JME08B2SN2AHRI reference: 21864325017.008.10172002.24EPA 4666879 →
CTM30B5ACS2+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21864324417.008.50181002.30EPA 4666885 →
CTM30B5ACS2+JMC12B2SN1Cold climate designationAHRI reference: 21864323217.008.50180002.32EPA 4666897 →
CTU30B5XCS2+TXV+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 21864321317.008.50184002.30EPA 4666916 →
CTF30B5ACS2+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 21864320717.008.50184002.30EPA 4666922 →
CTM30B5ACS2+JME08B2SN2AHRI reference: 21864319517.008.10172002.22EPA 4666934 →
CTF36B5ADS2+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 21868896617.008.50181002.38EPA 4678305 →
CTU36B5XDS2+TXV+ furnace: LP9C080B12MP13Cold climate designationAHRI reference: 21868896517.008.50181002.38EPA 4678306 →
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21868896017.008.50181002.38EPA 4678311 →
CTF36B5ADS2+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21868895917.008.50181002.38EPA 4678312 →
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21868894917.008.50181002.38EPA 4678322 →