Luxaire / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 4

342 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19342 / 342
EER2 · BTU/Wh11–12342 / 342
HSPF2 · BTU/Wh8.5–9.5342 / 342
Cooling capacity · BTU/h23,000342 / 342
Heating capacity at 47°F / 8.3°C · BTU/h23,000342 / 342
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900342 / 342
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400342 / 342
COP at 5°F / −15°C2342 / 342
Equipment / loop typeHP - Split System342 / 342
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)342 / 342
Compressor stagingContinuously variable342 / 342
Connected capabilityNo342 / 342

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852040319.009.50188002.00EPA 4642551
CTF30A5ADS2+ furnace: Z9ES060A10SMPS1AHRI reference: 21852022719.009.00185002.00EPA 4642727
CTF30A5ADS2+ furnace: Z8ET060A12LMPS1AHRI reference: 21852022319.009.50185002.00EPA 4642731
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 21863735319.009.50181002.00EPA 4664136
CTF36B5ADS2+JME12B2SN2AHRI reference: 21863734719.009.50181002.00EPA 4664142
CTU36B5XDS2+JME08B2SN2+TXVAHRI reference: 21863734119.009.00178002.00EPA 4664147
CTF36B5ADS2+JME08B2SN2AHRI reference: 21863733519.009.00178002.00EPA 4664151
CTF36B5ADS1+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 21439668418.009.50192002.00EPA 3436978
CTF30B5ACS1+JMC12B2SN1Cold climate designationAHRI reference: 21439669418.009.50190002.00EPA 3436983
CTF36B5ADS1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21439711118.009.50188002.00EPA 3437012
CTF30B5ACS1+JMET08BS2N1Cold climate designationAHRI reference: 21439712118.009.50182002.00EPA 3437017
CTF36B5ADS1+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21439666418.009.50189002.00EPA 3437293
CTF36B5ADS1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 21439666918.009.50184002.00EPA 3437298
CTF30B5ACS1+JMVT12BC2N1Cold climate designationAHRI reference: 21439625818.009.50190002.00EPA 3437445
CTM30B5ACS1+JMC12B2SN1Cold climate designationAHRI reference: 21439626318.009.50190002.00EPA 3437450
CTF36B5ADS1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 21439624818.009.50186002.00EPA 3437500
CTF30B5ACS1+JMET12BS2N1Cold climate designationAHRI reference: 21439837518.009.50185002.00EPA 3437773
CTF36B5ADS1+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 21439794918.009.50188002.00EPA 3437835
CTF36B5ADS1+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21439795418.009.50188002.00EPA 3437840
CTF36B5ADS1+ furnace: LP9C060B12MP13Cold climate designationAHRI reference: 21439795918.009.50188002.00EPA 3437845

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →