SL22KLV-024-230A**
DAVE LENNOX SIGNATURE DLSC SL22KLV SERIES · DAVE LENNOX SIGNATURE SL22KLV SERIES · source records, page 2
106 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for SL22KLV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 106 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.9–20.5 | 106 / 106 |
| EER2 · BTU/Wh | 11.5–13.2 | 106 / 106 |
| HSPF2 · BTU/Wh | 8.2–10.5 | 106 / 106 |
| Cooling capacity · BTU/h | 21,800–23,200 | 106 / 106 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,900–24,000 | 106 / 106 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,600–28,800 | 106 / 106 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,700–23,000 | 106 / 106 |
| COP at 5°F / −15°C | 1.74–2.3 | 106 / 106 |
| Equipment / loop type | HP - Split System | 106 / 106 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 106 / 106 |
| Compressor staging | Continuously variable | 106 / 106 |
| Connected capability | No | 106 / 106 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40[C,U]T-48B-**+TDR+ furnace: EL297UH045XV36B*Cold climate designationAHRI reference: 216968305 | 20.00 | 8.50 | 18000 | 1.86 | EPA 3996719 → |
CK40[C,U]T-48B-**+TDR+ furnace: EL297UH070XV36B*Cold climate designationAHRI reference: 216968306 | 20.00 | 8.50 | 17900 | 1.86 | EPA 3996720 → |
CBK48MVT-030-230-**Cold climate designationAHRI reference: 216968308 | 20.00 | 9.00 | 21400 | 2.10 | EPA 3996722 → |
CBK48MVT-018/024-230-**Cold climate designationAHRI reference: 216776013 | 19.50 | 9.00 | 21800 | 2.14 | EPA 3992699 → |
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH080NV48B*Cold climate designationAHRI reference: 216776025 | 19.50 | 8.20 | 22800 | 1.78 | EPA 3992711 → |
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH090V36B*Cold climate designationAHRI reference: 216776026 | 19.50 | 8.20 | 22800 | 1.78 | EPA 3992712 → |
CK40[C,U]T-30B-**+TDR+ furnace: SL297UH040NV36B*Cold climate designationAHRI reference: 216776029 | 19.50 | 8.20 | 22800 | 1.78 | EPA 3992715 → |
CK40[C,U]T-30B-**+TDR+ furnace: SLP99UH070XV36B*Cold climate designationAHRI reference: 216776031 | 19.50 | 8.20 | 22800 | 1.78 | EPA 3992717 → |
CK40HT-42B-**+TDR+ furnace: SL280UH080NV48B*Cold climate designationAHRI reference: 216776034 | 19.50 | 9.80 | 22400 | 2.26 | EPA 3992719 → |
CK40[C,U]T-30B-**+TDR+ furnace: EL297UH070XV36B*Cold climate designationAHRI reference: 216776033 | 19.50 | 8.20 | 22800 | 1.78 | EPA 3992720 → |
CK40HT-42C-**+TDR+ furnace: SL280UH080NV60C*Cold climate designationAHRI reference: 216776039 | 19.50 | 9.50 | 22200 | 2.08 | EPA 3992725 → |
CK40HT-42C-**+TDR+ furnace: EL297UH110XV48C*Cold climate designationAHRI reference: 216776048 | 19.50 | 9.50 | 22200 | 2.06 | EPA 3992734 → |
CK40[C,U]T-48C-**+TDR+ furnace: SL297UH080NV48C*Cold climate designationAHRI reference: 216968287 | 19.50 | 8.50 | 17900 | 1.86 | EPA 3996701 → |
CK40[C,U]T-48C-**+TDR+ furnace: SLP99UH090XV48C*Cold climate designationAHRI reference: 216968290 | 19.50 | 8.50 | 17800 | 1.88 | EPA 3996704 → |
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH090XV48C*Cold climate designationAHRI reference: 216968294 | 19.50 | 8.50 | 17800 | 1.88 | EPA 3996708 → |
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XV48C*Cold climate designationAHRI reference: 216968296 | 19.50 | 8.50 | 17800 | 1.86 | EPA 3996710 → |
CK40[C,U]T-48B-**+TDR+ furnace: SL280UH090V48B*Cold climate designationAHRI reference: 216968300 | 19.50 | 8.50 | 17900 | 1.86 | EPA 3996714 → |
CK40[C,U]T-48B-**+TDR+ furnace: SL280UH090XV48B*Cold climate designationAHRI reference: 216968301 | 19.50 | 8.50 | 17900 | 1.86 | EPA 3996715 → |
CK40HT-42B-**+TDR+ furnace: SL297UH060NV36B*Cold climate designationAHRI reference: 216776109 | 19.50 | 10.20 | 22400 | 2.24 | EPA 4480460 → |
CK40HT-42B-**+TDR+ furnace: SL297UH040NV36B*Cold climate designationAHRI reference: 216776108 | 19.50 | 10.20 | 22400 | 2.24 | EPA 4480461 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →