Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-048-230A**

MERIT ML17XP1 Series · source records, page 3

317 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.8BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 317 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.8317 / 317
EER2 · BTU/Wh12–13317 / 317
HSPF2 · BTU/Wh8–8.5317 / 317
Cooling capacity · BTU/h46,000–48,000317 / 317
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000317 / 317
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800317 / 317
Heating capacity at 5°F / −15°C · BTU/h24,200–26,000317 / 317
COP at 5°F / −15°C2.16–2.38317 / 317
Equipment / loop typeHP - Split System317 / 317
Refrigerant / source-reported GWPR-410A (GWP:2088)317 / 317
Compressor stagingSingle stage317 / 317
Connected capabilityNo317 / 317

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CHX35-51/61C-**-*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21005118015.408.30256002.32EPA 2454952
C35-60C+TDR+TXV+ furnace: SL280UH090XV60C*AHRI reference: 21005102515.408.30256002.34EPA 2454958
C35-60C+TDR+TXV+ furnace: SL280UH110V60C*AHRI reference: 21005102715.408.30254002.32EPA 2454959
C35-49C+TDR+TXV+ furnace: EL280UH110E48C*AHRI reference: 21005093315.408.10254002.26EPA 2454961
C35-49C+TDR+TXV+ furnace: EL280UH110XE60C*AHRI reference: 21005093515.408.10254002.26EPA 2454963
CX35-48C+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21005127215.408.10244002.20EPA 2454976
C35-48C+TDR+TXV+ furnace: ML180UH110V60C*AHRI reference: 21005090815.408.10244002.22EPA 2454983
C35-48C+TDR+TXV+ furnace: ML193UH110XE60C*AHRI reference: 21005091115.408.10244002.18EPA 2454986
CBA27UHE-048-230*+TDRAHRI reference: 21005103615.408.50244002.34EPA 2454987
CX35-49C+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21005130915.408.10254002.26EPA 2454994
CHX35-51/61C-**-*+TDR+ furnace: ML180UH110V60C*AHRI reference: 21005117815.408.30256002.30EPA 2455043
CX35-60C+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21005137115.408.30254002.32EPA 2455050
C35-49C+TDR+TXV+ furnace: SL280UH100NV60C*AHRI reference: 21005095715.408.10254002.26EPA 2455086
CHX35-51/61C-**-*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21005116915.408.30254002.28EPA 2455108
C35-60C+TDR+TXV+ furnace: ML193UH110XE48C*AHRI reference: 21005101615.408.10252002.36EPA 2455136
CX35-60C+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21005135515.408.10252002.34EPA 2455182
CX35-49C+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21005130015.408.10250002.24EPA 2455184
C35-60C+TDR+TXV+ furnace: SL280UH110XV60C*AHRI reference: 21005102815.408.30254002.32EPA 2455194
CX35-49C+TDR+ furnace: ML180UH110V60C*AHRI reference: 21005129715.408.10254002.26EPA 2455637
C35-49C+TDR+TXV+ furnace: ML180UH110V60C*AHRI reference: 21005094515.408.10254002.26EPA 2457157

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →