SEER2 range15.2–15.8BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 317 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.8317 / 317
EER2 · BTU/Wh12–13317 / 317
HSPF2 · BTU/Wh8–8.5317 / 317
Cooling capacity · BTU/h46,000–48,000317 / 317
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000317 / 317
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800317 / 317
Heating capacity at 5°F / −15°C · BTU/h24,200–26,000317 / 317
COP at 5°F / −15°C2.16–2.38317 / 317
Equipment / loop typeHP - Split System317 / 317
Refrigerant / source-reported GWPR-410A (GWP:2088)317 / 317
Compressor stagingSingle stage317 / 317
Connected capabilityNo317 / 317

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-48C-0*+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21462443815.208.00248002.18EPA 3474305 →
CK40HT-48C-0*+TDR+ furnace: EL280UH110E48C*AHRI reference: 21462443915.208.10246002.16EPA 3474307 →
CK40HT-48C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462444115.208.00246002.18EPA 3474308 →
CK40HT-48C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462444015.208.00246002.18EPA 3474309 →
CK40HT-48C-0*+TDR+ furnace: ML180UH090E60C*AHRI reference: 21462444815.208.00244002.18EPA 3474311 →
CK40CT-49C-0*+TDR+ furnace: SLP99UH090XV36C*AHRI reference: 21462470315.208.10250002.22EPA 3475008 →
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462471615.208.10242002.18EPA 3475009 →
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462471815.208.10242002.18EPA 3475010 →
CK40CT-50/60C-0*+TDR+ furnace: ML180UH090E60C*AHRI reference: 21462472915.208.00242002.18EPA 3475012 →
CK40CT-50/60C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462474615.208.10244002.20EPA 3475013 →
CK40HT-48C-0*+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21462445815.208.00248002.18EPA 3475266 →
CK40HT-48C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462446315.208.10248002.20EPA 3475267 →
CK40HT-51/61C-0*+TDR+ furnace: EL297UH090XV36C*AHRI reference: 21462449215.208.10254002.28EPA 3475272 →
CK40HT-51/61C-0*+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21462449715.208.10254002.28EPA 3475273 →
CK40HT-51/61C-0*+TDR+ furnace: ML180UH110E60C*AHRI reference: 21462450315.208.30256002.30EPA 3475275 →
CK40HT-51/61C-0*+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21462450615.208.30256002.30EPA 3475277 →
CK40HT-51/61C-0*+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21462450715.208.30256002.30EPA 3475278 →
CK40HT-51/61C-0*+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21462451115.208.30256002.28EPA 3475280 →
CK40HT-51/61C-0*+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21462451715.208.30260002.32EPA 3475282 →
CK40HT-51/61C-0*+TDR+ furnace: SL280UH090V60C*AHRI reference: 21462452015.208.30260002.32EPA 3475284 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.