Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-042-230A**

MERIT ML17XP1 Series · source records, page 5

209 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–42,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-042-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 209 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6209 / 209
EER2 · BTU/Wh12.5–13209 / 209
HSPF2 · BTU/Wh7.8–8.3209 / 209
Cooling capacity · BTU/h40,000–42,000209 / 209
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,000209 / 209
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,800209 / 209
Heating capacity at 5°F / −15°C · BTU/h10,400–22,000209 / 209
COP at 5°F / −15°C2–2.22209 / 209
Equipment / loop typeHP - Split System209 / 209
Refrigerant / source-reported GWPR-410A (GWP:2088)209 / 209
Compressor stagingSingle stage209 / 209
Connected capabilityNo209 / 209

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-49C-0*+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21462439915.407.80198002.10EPA 3474281 →
CK40CT-49C-0*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21462440215.407.80198002.10EPA 3474282 →
CK40CT-49C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462441015.407.80199002.10EPA 3474289 →
CK40CT-48C-0*+TDR+ furnace: ML180UH110E60C*AHRI reference: 21462435615.407.80196002.10EPA 3474728 →
CK40CT-48C-0*+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21462435815.407.80196002.10EPA 3474738 →
CK40CT-48C-0*+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21462436215.407.80199002.10EPA 3474746 →
CK40CT-48C-0*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21462436115.407.80196002.10EPA 3474747 →
CK40CT-48C-0*+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21462436515.407.80199002.10EPA 3474748 →
CK40CT-48C-0*+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21462436815.407.80200002.10EPA 3474751 →
CK40CT-49C-0*+TDR+ furnace: EL280UH110E48C*AHRI reference: 21462438615.407.80196002.08EPA 3474760 →
CK40CT-49C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462438715.407.80199002.08EPA 3474761 →
CK40CT-49C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462438815.407.80199002.08EPA 3474762 →
CK40HT-48C-0*+TDR+ furnace: ML180UH110V60C*AHRI reference: 21462426815.407.80104002.08EPA 3474833 →
CK40HT-48C-0*+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21462428315.407.80202002.04EPA 3474840 →
CK40DT-48C-0*+TDR+ furnace: SL280DF110V60C*AHRI reference: 21462430415.408.30220002.14EPA 3474853 →
CK40HT-42B-0*+TDR+ furnace: EL280UH090E36B*AHRI reference: 21462415915.407.80199002.10EPA 3475991 →
CK40HT-42B-0*+TDR+ furnace: ML180UH070E36B*AHRI reference: 21462416515.407.80202002.12EPA 3476022 →
CK40HT-42B-0*+TDR+ furnace: ML180UH070V48B*AHRI reference: 21462416715.408.00220002.14EPA 3476032 →
CK40HT-42B-0*+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21462416815.407.80202002.12EPA 3476036 →
CK40HT-42B-0*+TDR+ furnace: ML180UH090E48B*AHRI reference: 21462416915.407.80200002.12EPA 3476039 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →