Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-036-230A**

MERIT ML17XP1 Series · source records, page 8

799 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CHX35-42C-**-*+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21100192916.408.00179002.18EPA 2469270
CHX35-42C-**-*+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21100193116.408.00181002.20EPA 2469272
CHX35-42C-**-*+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21100193216.408.00179002.18EPA 2469273
CHX35-42C-**-*+TDR+ furnace: EL297UH090XV48C*AHRI reference: 21319469216.408.00180002.20EPA 2633352
CHX35-42C-**-*+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21294512016.408.10180002.20EPA 2633869
CHX35-51/61C-**-*+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21294508416.408.10174002.18EPA 2633877
CHX35-42B-**-*+TDR+ furnace: ML180UH090XE48B*AHRI reference: 21294511916.408.10183002.28EPA 2633885
CHX35-42C-**-*+TDR+ furnace: EL297UH090XE48C*AHRI reference: 21363028716.408.00179002.22EPA 2836168
CRX35-48C-**-*+TDR+ furnace: SL280DF110V60C*AHRI reference: 21325804316.408.70191002.34EPA 2839513
CHX35-42C-**-*+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21343422116.408.00178002.20EPA 2842233
C35-48C+TDR+TXV+ furnace: EL297UH090XE48C*AHRI reference: 21380491616.408.00171002.12EPA 2856726
C35-48C+TDR+TXV+ furnace: ML193UH090XE36C*AHRI reference: 21380492016.407.80170002.14EPA 2856730
C35-48C+TDR+TXV+ furnace: ML296UH090XV48C*AHRI reference: 21380492816.408.00172002.12EPA 2856738
C35-48C+TDR+TXV+ furnace: SL297UH080NV48C*AHRI reference: 21380493616.407.80170002.12EPA 2856746
C35-48C+TDR+TXV+ furnace: SLP99UH090XV48C*AHRI reference: 21380493916.407.80170002.12EPA 2856749
C35-48C+TDR+TXV+ furnace: SLP99UH110XV60C*AHRI reference: 21380494116.407.80172002.14EPA 2856751
CX35-48C+TDR+ furnace: EL297UH090XE48C*AHRI reference: 21380495716.408.00171002.12EPA 2856768
CX35-48C+TDR+ furnace: ML193UH090XE36C*AHRI reference: 21380496116.407.80170002.14EPA 2856771
CX35-48C+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21380496916.408.00172002.12EPA 2856779
CX35-48C+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21380497116.407.80170002.12EPA 2856781

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →