Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-036-230A**

MERIT ML17XP1 Series · source records, page 36

799 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-36B+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21004931815.607.80174002.12EPA 2462026 →
C35-36B+TDR+TXV+ furnace: ML193UH030XE36B*AHRI reference: 21004851915.607.80174002.12EPA 2462049 →
CHX35-48B-**-*+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21004895215.607.80175002.20EPA 2462051 →
C35-36B+TDR+TXV+ furnace: ML196UH070XE48B*AHRI reference: 21004853415.607.80174002.08EPA 2462263 →
CHX35-42B-**-*+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21100189415.608.00187002.20EPA 2469251 →
CHX35-42B-**-*+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21319469015.608.10189002.26EPA 2633363 →
CHX35-48B-**-*+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21319447515.608.00178002.20EPA 2633581 →
CHX35-48B-**-*+TDR+ furnace: EL297UH070XE36B*AHRI reference: 21363028815.607.80174002.18EPA 2836162 →
CHX35-42B-**-*+TDR+ furnace: EL297UH070XE36B*AHRI reference: 21363028615.608.10188002.18EPA 2836172 →
CRX35-48C-**-*+TDR+ furnace: SLP99DF110XV60C*AHRI reference: 21325804715.608.60190002.26EPA 2839517 →
CRX35-30/36B-**-*+TDR+ furnace: EL280DF090E48B*AHRI reference: 21325800715.608.00187002.12EPA 2839575 →
CRX35-30/36C-**-*+TDR+ furnace: ML296DF090XV60C*AHRI reference: 21325802315.608.00189002.14EPA 2839590 →
CRX35-30/36C-**-*+TDR+ furnace: SL280DF080NV60C*AHRI reference: 21325802415.608.00189002.12EPA 2839592 →
CRX35-30/36C-**-*+TDR+ furnace: SLP99DF090XV36C*AHRI reference: 21325802715.608.00186002.12EPA 2839595 →
CRX35-30/36C-**-*+TDR+ furnace: EL297DF110XE60C*AHRI reference: 21343346215.608.00189002.12EPA 2842177 →
CK40HT-42B-0*+TDR+ furnace: EL297UH070XE36B*AHRI reference: 21462383315.608.10188002.18EPA 3475526 →
CK40HT-42B-0*+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21462383415.608.10189002.26EPA 3475528 →
CK40HT-42B-0*+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21462384215.608.00187002.20EPA 3475537 →
CK40HT-42B-0*+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21462385315.608.10188002.24EPA 3475554 →
CK40HT-42B-0*+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21462385415.608.10189002.24EPA 3475559 →