ML17XP1-036-230A**
MERIT ML17XP1 Series · source records, page 14
799 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 799 / 799 |
| EER2 · BTU/Wh | 12.2–14 | 799 / 799 |
| HSPF2 · BTU/Wh | 7.8–8.7 | 799 / 799 |
| Cooling capacity · BTU/h | 34,800–36,000 | 799 / 799 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,400–36,000 | 799 / 799 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,400–24,000 | 799 / 799 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–19,300 | 799 / 799 |
| COP at 5°F / −15°C | 2.06–2.36 | 799 / 799 |
| Equipment / loop type | HP - Split System | 799 / 799 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 799 / 799 |
| Compressor staging | Single stage | 799 / 799 |
| Connected capability | No | 799 / 799 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
C35-50/60C+TDR+TXV+ furnace: SL280UH100NV60C*AHRI reference: 210048651 | 16.20 | 8.10 | 17400 | 2.14 | EPA 2462250 → |
CX35-50/60C+TDR+ furnace: EL196UH110XE60C*AHRI reference: 210049355 | 16.20 | 7.80 | 17200 | 2.12 | EPA 2462261 → |
C35-50/60C+TDR+TXV+ furnace: EL196UH110XE60C*AHRI reference: 210048572 | 16.20 | 7.80 | 17200 | 2.12 | EPA 2462279 → |
CHX35-48B-**-*+TDR+ furnace: SL280UH090V36B*AHRI reference: 210048975 | 16.20 | 8.10 | 17400 | 2.24 | EPA 2462284 → |
CHX35-51/61C-**-*+TDR+ furnace: EL196UH090XE48C*AHRI reference: 210049000 | 16.20 | 8.00 | 17500 | 2.18 | EPA 2462287 → |
CHX35-42C-**-*+TDR+ furnace: EL195UH080NE48C*AHRI reference: 211001909 | 16.20 | 7.80 | 18100 | 2.20 | EPA 2469255 → |
CHX35-42C-**-*+TDR+ furnace: ML193UH090XE36C*AHRI reference: 211001926 | 16.20 | 8.00 | 18100 | 2.18 | EPA 2469267 → |
CHX35-42C-**-*+TDR+ furnace: SL297UH080NV48C*AHRI reference: 211001942 | 16.20 | 8.00 | 18300 | 2.22 | EPA 2469276 → |
CHX35-42C-**-*+TDR+ furnace: SLP99UH090XV36C*AHRI reference: 211001944 | 16.20 | 8.00 | 18200 | 2.22 | EPA 2469277 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH110XV48C*AHRI reference: 213194694 | 16.20 | 8.00 | 18200 | 2.22 | EPA 2633280 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH110XV60C*AHRI reference: 213194695 | 16.20 | 8.10 | 18200 | 2.20 | EPA 2633344 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH090XV36C*AHRI reference: 213194691 | 16.20 | 8.00 | 18200 | 2.22 | EPA 2633462 → |
CHX35-51/61C-**-*+TDR+ furnace: EL297UH090XV48C*AHRI reference: 213194477 | 16.20 | 8.00 | 17400 | 2.16 | EPA 2633522 → |
CHX35-51/61C-**-*+TDR+ furnace: EL297UH110XV60C*AHRI reference: 213194480 | 16.20 | 8.10 | 17600 | 2.18 | EPA 2633528 → |
CHX35-51/61C-**-*+TDR+ furnace: EL297UH090XV36C*AHRI reference: 213194476 | 16.20 | 8.00 | 17600 | 2.18 | EPA 2633559 → |
CHX35-51/61C-**-*+TDR+ furnace: EL297UH110XV48C*AHRI reference: 213194479 | 16.20 | 8.00 | 17600 | 2.18 | EPA 2633590 → |
CX35-50/60C+TDR+ furnace: ML180UH110XE60C*AHRI reference: 212945088 | 16.20 | 7.80 | 17300 | 2.12 | EPA 2633862 → |
C35-50/60C+TDR+TXV+ furnace: ML180UH110XE60C*AHRI reference: 212945081 | 16.20 | 7.80 | 17300 | 2.12 | EPA 2633875 → |
CX35-36B+TDR+ furnace: ML180UH070XE36B*AHRI reference: 212945086 | 16.20 | 7.80 | 17200 | 2.14 | EPA 2633898 → |
CHX35-48B-**-*+TDR+ furnace: ML180UH090XE48B*AHRI reference: 212945083 | 16.20 | 8.00 | 17200 | 2.24 | EPA 2633901 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →