SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 799 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8799 / 799
EER2 · BTU/Wh12.2–14799 / 799
HSPF2 · BTU/Wh7.8–8.7799 / 799
Cooling capacity · BTU/h34,800–36,000799 / 799
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000799 / 799
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000799 / 799
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300799 / 799
COP at 5°F / −15°C2.06–2.36799 / 799
Equipment / loop typeHP - Split System799 / 799
Refrigerant / source-reported GWPR-410A (GWP:2088)799 / 799
Compressor stagingSingle stage799 / 799
Connected capabilityNo799 / 799

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-48C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21462410216.407.80170002.12EPA 3476675
CK40CT-48C-0*+TDR+ furnace: SL297UH080NV48C*AHRI reference: 21462410816.407.80170002.12EPA 3476683
CK40CT-48C-0*+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21462411316.407.80172002.14EPA 3476684
CK40CT-48C-0*+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21462411116.407.80170002.12EPA 3476686
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110E48C*AHRI reference: 21462412016.407.80170002.12EPA 3476692
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21462412216.407.80171002.16EPA 3476693
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21462412116.407.80171002.16EPA 3476694
CK40CT-50/60C-0*+TDR+ furnace: ML180UH090E60C*AHRI reference: 21462413016.407.80170002.12EPA 3476704
CK40HT-42C-0*+TDR+ furnace: EL296UH090XE48C*AHRI reference: 21572829616.408.00179002.22EPA 3649668
CK40HT-42C-0*+TDR+ furnace: EL296UH090XV48C*AHRI reference: 21572829816.408.00180002.20EPA 3649670
CK40HT-42C-0*+TDR+ furnace: EL296UH110XE60C*AHRI reference: 21572830016.408.00178002.20EPA 3649671
CHX35-42B-**-*+TDR+ furnace: ML180UH070V48B*AHRI reference: 21100189116.208.10186002.30EPA 2454696
CHX35-42B-**-*+TDR+ furnace: SL280UH090V36B*AHRI reference: 21100190316.208.10184002.28EPA 2454702
CHX35-42C-**-*+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21100193416.208.10182002.20EPA 2454709
CHX35-42C-**-*+TDR+ furnace: SL280UH090V60C*AHRI reference: 21100193716.208.10184002.20EPA 2454714
CHX35-42C-**-*+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21100193816.208.10184002.20EPA 2454716
CHX35-42C-**-*+TDR+ furnace: SL297UH080NV60C*AHRI reference: 21100194316.208.10184002.20EPA 2454721
CHX35-42C-**-*+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21100194716.208.10182002.20EPA 2454723
CBA25UHV-042-230-**AHRI reference: 21105629416.208.10174002.22EPA 2454745