Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-030-230A**

MERIT ML17XP1 Series · source records, page 9

524 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 524 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2524 / 524
EER2 · BTU/Wh12.2–13.5524 / 524
HSPF2 · BTU/Wh7.8–8.6524 / 524
Cooling capacity · BTU/h28,200–30,600524 / 524
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000524 / 524
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600524 / 524
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400524 / 524
COP at 5°F / −15°C1.96–2.38524 / 524
Equipment / loop typeHP - Split System524 / 524
Refrigerant / source-reported GWPR-410A (GWP:2088)524 / 524
Compressor stagingSingle stage524 / 524
Connected capabilityNo524 / 524

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-36A+TDR+ furnace: SL280UH070V36A*AHRI reference: 21004723415.808.10144002.26EPA 2461258
CX35-36B+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21004727015.808.10144002.26EPA 2461265
C35-30B+TDR+TXV+ furnace: SL280UH080NV48B*AHRI reference: 21004681215.808.10143002.20EPA 2461503
CX35-30B+TDR+ furnace: ML180UH070V36B*AHRI reference: 21004719715.808.10145002.22EPA 2461729
C35-36B+TDR+TXV+ furnace: ML193UH030XE36B*AHRI reference: 21004689015.808.10142002.26EPA 2461982
CHX35-30A-**-*+TDR+ furnace: EL280UH045E36A*AHRI reference: 21004703515.807.80138002.00EPA 2461983
C35-36B+TDR+TXV+ furnace: ML193UH045XE36B*AHRI reference: 21004689115.808.10143002.26EPA 2461987
C35-36B+TDR+TXV+ furnace: EL195UH060NE36B*AHRI reference: 21004686315.808.10142002.26EPA 2461994
CX35-30B+TDR+ furnace: EL280UH090E36B*AHRI reference: 21004718415.808.10143002.24EPA 2461995
CBA27UHE-030-230*+TDRAHRI reference: 21004691715.808.50147002.36EPA 2462237
CX35-30A+TDR+ furnace: EL280UH045E36A*AHRI reference: 21004715615.808.10143002.24EPA 2462253
CX35-36B+TDR+ furnace: EL195UH060NE36B*AHRI reference: 21004723815.808.10142002.26EPA 2462265
CHX35-30B-**-*+TDR+ furnace: EL195UH060NE36B*AHRI reference: 21086985115.807.80138002.08EPA 2467462
CHX35-30B-**-*+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21086984915.807.80136002.08EPA 2467463
CHX35-30B-**-*+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21086986815.807.80136002.10EPA 2467902
CHX35-30B-**-*+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21086986715.807.80138002.08EPA 2467903
CHX35-30B-**-*+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21086988015.808.00137002.10EPA 2467913
CHX35-30B-**-*+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21086988115.808.00137002.08EPA 2467914
CHX35-30B-**-*+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21086987915.808.00137002.08EPA 2467915
CBA38MV-036-230*+TDRAHRI reference: 21180699215.808.10149002.36EPA 2468005

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →