Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-024-230A**

MERIT ML17XP1 Series · source records, page 5

486 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 486 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17486 / 486
EER2 · BTU/Wh12.5–14486 / 486
HSPF2 · BTU/Wh7.8–8.2486 / 486
Cooling capacity · BTU/h22,400–24,000486 / 486
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600486 / 486
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700486 / 486
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500486 / 486
COP at 5°F / −15°C2–2.18486 / 486
Equipment / loop typeHP - Split System486 / 486
Refrigerant / source-reported GWPR-410A (GWP:2088)486 / 486
Compressor stagingSingle stage486 / 486
Connected capabilityNo486 / 486

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
C35-30A+TDR+TXV+ furnace: SL280UH070XV36A*AHRI reference: 21003993116.407.80104002.04EPA 2814587
CX35-24A+TDR+ furnace: ML180UH045V36A*AHRI reference: 21004032316.407.80102002.02EPA 2814588
CHX35-30A-**-*+TDR+ furnace: SL280UH070V36A*AHRI reference: 21004020116.408.10106002.12EPA 2814593
CHX35-24A-**-*+TDR+ furnace: ML180UH045V36A*AHRI reference: 21004016016.407.80104002.06EPA 2814594
C35-24B+TDR+TXV+ furnace: SL280UH080NV48B*AHRI reference: 21003989116.407.80104002.04EPA 2814597
CHX35-30B-**-*+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21004024216.407.80102002.02EPA 2814598
C35-30B+TDR+TXV+ furnace: SL280UH080NV48B*AHRI reference: 21003999316.407.80104002.06EPA 2814602
CHX35-30A-**-*+TDR+ furnace: ML180UH045E36A*AHRI reference: 21004018916.408.00102002.08EPA 2814606
C35-24B+TDR+TXV+ furnace: SL280UH090V36B*AHRI reference: 21003989416.407.80104002.08EPA 2814609
CX35-30A+TDR+ furnace: SL280UH070V36A*AHRI reference: 21004043716.407.80104002.04EPA 2814611
C35-30A+TDR+TXV+ furnace: ML180UH070V36A*AHRI reference: 21003992316.407.80104002.06EPA 2814612
C35-24B+TDR+TXV+ furnace: ML180UH090E48B*AHRI reference: 21003986616.407.80104002.08EPA 2814616
C35-30A+TDR+TXV+ furnace: EL280UH045E36A*AHRI reference: 21003990816.407.80102002.06EPA 2814620
CX35-24B+TDR+ furnace: EL280UH090XE48B*AHRI reference: 21004035316.407.80104002.04EPA 2814623
CHX35-30B-**-*+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21004020516.407.80106002.02EPA 2814630
C35-24B+TDR+TXV+ furnace: ML180UH070E36B*AHRI reference: 21003985916.407.80104002.04EPA 2814631
C35-30B+TDR+TXV+ furnace: ML180UH070V48B*AHRI reference: 21003996616.408.00104002.04EPA 2814637
C35-30B+TDR+TXV+ furnace: EL280UH090E48B*AHRI reference: 21003994816.408.00104002.06EPA 2814640
C35-24A+TDR+TXV+ furnace: EL280UH045E36A*AHRI reference: 21003980016.407.80102002.04EPA 2814646
CX35-24B+TDR+ furnace: ML180UH070E36B*AHRI reference: 21004036316.407.80104002.04EPA 2814648