Lennox / AIR-SOURCE HEAT PUMP

ML17XP1-024-230A**

MERIT ML17XP1 Series · source records, page 18

486 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for ML17XP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 486 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17486 / 486
EER2 · BTU/Wh12.5–14486 / 486
HSPF2 · BTU/Wh7.8–8.2486 / 486
Cooling capacity · BTU/h22,400–24,000486 / 486
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600486 / 486
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700486 / 486
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500486 / 486
COP at 5°F / −15°C2–2.18486 / 486
Equipment / loop typeHP - Split System486 / 486
Refrigerant / source-reported GWPR-410A (GWP:2088)486 / 486
Compressor stagingSingle stage486 / 486
Connected capabilityNo486 / 486

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-30B-0*+TDR+ furnace: EL280UH090E36B*AHRI reference: 21462358116.007.80106002.00EPA 3474578 →
CK40CT-30B-0*+TDR+ furnace: ML180UH090V48B*AHRI reference: 21462359316.007.80106002.02EPA 3474592 →
CK40CT-30B-0*+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21462359816.007.80102002.00EPA 3474598 →
CK40CT-30B-0*+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21462360216.007.80104002.02EPA 3474601 →
CK40DT-30/36B-0*+TDR+ furnace: EL280DF090E48B*AHRI reference: 21462348416.008.20112002.08EPA 3474771 →
CK40DT-30/36B-0*+TDR+ furnace: ML180DF070E36B*AHRI reference: 21462348916.008.10112002.10EPA 3474776 →
CK40DT-30/36B-0*+TDR+ furnace: SLP99DF070XV36B*AHRI reference: 21462349716.008.10111002.08EPA 3474784 →
CK40DT-30/36C-0*+TDR+ furnace: EL297DF090XE48C*AHRI reference: 21462349916.008.20113002.10EPA 3474787 →
CK40CT-24A-0*+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21462350816.007.80106002.02EPA 3474791 →
CK40CT-24A-0*+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21462350716.007.80106002.02EPA 3474793 →
CK40CT-24A-0*+TDR+ furnace: EL280UH070E36A*AHRI reference: 21462351016.007.80106002.02EPA 3474794 →
CK40CT-24A-0*+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21462351116.007.80106002.02EPA 3474797 →
CK40CT-24B-0*+TDR+ furnace: EL280UH090E36B*AHRI reference: 21462352916.007.80106002.02EPA 3474809 →
CK40CT-24B-0*+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21462353316.007.80104002.02EPA 3474813 →
CK40CT-24B-0*+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21462354516.007.80106002.06EPA 3474830 →
CK40HT-24A-0*+TDR+ furnace: EL280UH070E36A*AHRI reference: 21462341816.007.80105002.04EPA 3475418 →
CBK45UHET-024-230-0*AHRI reference: 21486128116.007.80104002.08EPA 3553525 →
CBK45UHET-030-230-0*AHRI reference: 21486128416.008.10108002.06EPA 3553527 →
CBK45UHVT-030-230-0*AHRI reference: 21486126916.008.10104002.06EPA 3553594 →
CBK47UHET-030-230-0*AHRI reference: 21486127016.008.20108002.16EPA 3553596 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →