ML15KSPV-024-230A**
ML15KSPV SERIES · ML15KSPV Series · Merit ML15KSPV SERIES · source records, page 4
110 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for ML15KSPV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 110 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 110 / 110 |
| EER2 · BTU/Wh | 9–9.7 | 110 / 110 |
| HSPF2 · BTU/Wh | 8.1–8.9 | 110 / 110 |
| Cooling capacity · BTU/h | 22,600–24,400 | 110 / 110 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,400–25,000 | 110 / 110 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,900–18,900 | 110 / 110 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,900–18,900 | 110 / 110 |
| COP at 5°F / −15°C | 1.8–1.9 | 110 / 110 |
| Equipment / loop type | HP - Split System | 110 / 110 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 110 / 110 |
| Compressor staging | Continuously variable | 110 / 110 |
| Connected capability | No | 110 / 110 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-30B-**+TDR+ furnace: ML180UH070V36B*Cold climate designationAHRI reference: 218617658 | 16.00 | 8.10 | 18100 | 1.80 | EPA 4657434 → |
CK40HT-30B-**+TDR+ furnace: EL297UH045XV36B*Cold climate designationAHRI reference: 218617656 | 16.00 | 8.10 | 18200 | 1.80 | EPA 4657436 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 218617655 | 16.00 | 8.10 | 18000 | 1.80 | EPA 4657437 → |
CK40HT-30A-**+TDR+ furnace: ML180UH045V36A*Cold climate designationAHRI reference: 218617652 | 16.00 | 8.40 | 17900 | 1.80 | EPA 4657440 → |
CK40HT-30A-**+TDR+ furnace: EL280UH070XE36A*Cold climate designationAHRI reference: 218617650 | 16.00 | 8.40 | 17900 | 1.80 | EPA 4657442 → |
CK40HT-30A-**+TDR+ furnace: SL280UH070XV36A*Cold climate designationAHRI reference: 218617649 | 16.00 | 8.40 | 18000 | 1.80 | EPA 4657443 → |
CK40HT-24B-**+TDR+ furnace: ML193UH030XE36B*Cold climate designationAHRI reference: 218617643 | 16.00 | 8.10 | 18400 | 1.80 | EPA 4657449 → |
CK40HT-24B-**+TDR+ furnace: EL297UH045XV36B*Cold climate designationAHRI reference: 218617640 | 16.00 | 8.10 | 18300 | 1.80 | EPA 4657452 → |
CK40[C,U]T-36B-**+TDR+ furnace: ML193UH045XE36B*Cold climate designationAHRI reference: 218617634 | 16.00 | 8.10 | 18300 | 1.80 | EPA 4657458 → |
CK40[C,U]T-36B-**+TDR+ furnace: ML196UH030XE36B*Cold climate designationAHRI reference: 218617632 | 16.00 | 8.10 | 18100 | 1.80 | EPA 4657460 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL280UH070XE36A*Cold climate designationAHRI reference: 218617620 | 16.00 | 8.10 | 18000 | 1.80 | EPA 4657472 → |
CK40[C,U]T-24B-**+TDR+ furnace: ML296UH070XV36B*Cold climate designationAHRI reference: 218617617 | 16.00 | 8.10 | 18200 | 1.80 | EPA 4657475 → |
CK40[C,U]T-24B-**+TDR+ furnace: ML180UH090V48B*Cold climate designationAHRI reference: 218617613 | 16.00 | 8.10 | 18400 | 1.80 | EPA 4657479 → |
CK40HT-24B-**+TDR+ furnace: SL297UH060NV36B*Cold climate designationAHRI reference: 218617594 | 16.00 | 8.10 | 18200 | 1.80 | EPA 4657498 → |
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045XE36A*Cold climate designationAHRI reference: 218617583 | 16.00 | 8.10 | 18200 | 1.80 | EPA 4657509 → |
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045E36A*Cold climate designationAHRI reference: 218617581 | 16.00 | 8.10 | 18200 | 1.80 | EPA 4657511 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL280UH070E36A*Cold climate designationAHRI reference: 218617578 | 16.00 | 8.10 | 18000 | 1.80 | EPA 4657514 → |
CK40DT-24B-**+TDR+ furnace: ML193DF070XE36B*Cold climate designationAHRI reference: 218617673 | 15.90 | 8.20 | 18200 | 1.80 | EPA 4657419 → |
CK40DT-24B-**+TDR+ furnace: SLP99DF070XV36B*Cold climate designationAHRI reference: 218617670 | 15.90 | 8.20 | 18200 | 1.80 | EPA 4657422 → |
CK40HT-24B-**+TDR+ furnace: ML193UH045XE36B*Cold climate designationAHRI reference: 218617644 | 15.90 | 8.10 | 18400 | 1.80 | EPA 4657448 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →