ML15KSPV-018-230A**
ML15KSPV SERIES · ML15KSPV Series · Merit ML15KSPV SERIES
83 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for ML15KSPV-018-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 83 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.2 | 83 / 83 |
| EER2 · BTU/Wh | 10.2–11 | 83 / 83 |
| HSPF2 · BTU/Wh | 8.1–8.8 | 83 / 83 |
| Cooling capacity · BTU/h | 17,900–18,900 | 83 / 83 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–18,600 | 83 / 83 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,000–15,600 | 83 / 83 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,600–14,000 | 83 / 83 |
| COP at 5°F / −15°C | 1.8–2 | 83 / 83 |
| Equipment / loop type | HP - Split System | 83 / 83 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 83 / 83 |
| Compressor staging | Continuously variable | 83 / 83 |
| Connected capability | No | 83 / 83 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-30A-**+TDR+ furnace: EL280UH045E36A*Cold climate designationAHRI reference: 218617523 | 17.20 | 8.80 | 13700 | 2.00 | EPA 4657569 → |
CK40[C,U]T-24B-**+TDR+ furnace: ML193UH030XE36B*Cold climate designationAHRI reference: 218617538 | 17.10 | 8.50 | 14000 | 1.90 | EPA 4657554 → |
CK40HT-24B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 218617554 | 16.80 | 8.40 | 13900 | 1.90 | EPA 4657538 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 218617565 | 16.70 | 8.40 | 13900 | 1.90 | EPA 4657527 → |
CK40HT-30A-**+TDR+ furnace: ML180UH045V36A*Cold climate designationAHRI reference: 218617563 | 16.60 | 8.60 | 13800 | 2.00 | EPA 4657529 → |
CK40HT-30A-**+TDR+ furnace: ML180UH030V36A*Cold climate designationAHRI reference: 218617562 | 16.60 | 8.60 | 13700 | 2.00 | EPA 4657530 → |
CK40HT-30B-**+TDR+ furnace: SLP99UH070XV36B*Cold climate designationAHRI reference: 218617529 | 16.60 | 8.40 | 13900 | 1.90 | EPA 4657563 → |
CK40HT-24B-**+TDR+ furnace: SLP99UH070XV36B*Cold climate designationAHRI reference: 218617520 | 16.60 | 8.40 | 13900 | 1.90 | EPA 4657572 → |
CK40HT-30B-**+TDR+ furnace: ML180UH070V36B*Cold climate designationAHRI reference: 218617568 | 16.50 | 8.40 | 13800 | 1.90 | EPA 4657524 → |
CK40HT-30A-**+TDR+ furnace: EL280UH070XE36A*Cold climate designationAHRI reference: 218617561 | 16.50 | 8.60 | 13800 | 2.00 | EPA 4657531 → |
CK40HT-24B-**+TDR+ furnace: ML193UH030XE36B*Cold climate designationAHRI reference: 218617558 | 16.50 | 8.40 | 13900 | 1.90 | EPA 4657534 → |
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH030V36A*Cold climate designationAHRI reference: 218617542 | 16.50 | 8.30 | 13900 | 1.90 | EPA 4657550 → |
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH045V36A*Cold climate designationAHRI reference: 218617534 | 16.50 | 8.40 | 13900 | 1.90 | EPA 4657558 → |
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH030V36A*Cold climate designationAHRI reference: 218617533 | 16.50 | 8.40 | 13900 | 1.90 | EPA 4657559 → |
CK40HT-30A-**+TDR+ furnace: EL280UH070E36A*Cold climate designationAHRI reference: 218617524 | 16.50 | 8.60 | 13800 | 2.00 | EPA 4657568 → |
CBK48MVT-018/024-230-**Cold climate designationAHRI reference: 218616022 | 16.40 | 8.80 | 13400 | 1.90 | EPA 4657404 → |
CK40HT-24A-**+TDR+ furnace: ML180UH045V36A*Cold climate designationAHRI reference: 218617552 | 16.40 | 8.30 | 13900 | 1.90 | EPA 4657540 → |
CK40HT-24A-**+TDR+ furnace: ML180UH030V36A*Cold climate designationAHRI reference: 218617551 | 16.40 | 8.30 | 13900 | 1.90 | EPA 4657541 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH070V36B*Cold climate designationAHRI reference: 218617546 | 16.40 | 8.20 | 13900 | 1.90 | EPA 4657546 → |
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH045V36A*Cold climate designationAHRI reference: 218617543 | 16.40 | 8.30 | 13900 | 1.90 | EPA 4657549 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →