ML14KP1-042-233A**
MERIT ML14KP1 Series
81 published source records · source checked Sep 21, 2026
Commercial records can use SEER, SEER2, EER, EER2 or IEER. These metrics are labeled separately and are not converted or treated as interchangeable.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Reported metrics & equipment details
Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–15.5 | 81 / 81 |
| EER2 · BTU/Wh | 12.6–13.2 | 81 / 81 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 81 / 81 |
| Cooling capacity · kBTU/h | 0 | 81 / 81 |
| Heating capacity at 17°F / −8.3°C · kBTU/h | 24.6–25.8 | 81 / 81 |
| Commercial equipment class | Very Small HP | 81 / 81 |
| System construction | Split | 81 / 81 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 81 / 81 |
| Refrigerant | R-454B | 81 / 81 |
Matched systems
Each row retains its own equipment and test conditions. Open the record for all specifications.
| Indoor unit / required furnace | SEER2BTU/Wh | Record & comparison |
|---|---|---|
CBK45UHVT-042-230-**Very Small HP | 15.5 | EPA 4517487 → |
CBK47UHET-042-230-**Very Small HP | 15.5 | EPA 4517489 → |
CBK47UHET-048-230-**Very Small HP | 15.5 | EPA 4517490 → |
CBK47UHET-048-460-**Very Small HP | 15.5 | EPA 4517491 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517494 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517495 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517496 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517497 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517504 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517505 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517506 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517507 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517509 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517512 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517515 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517516 → |
CK40[C,U]T-48C-**+TDRVery Small HP | 15.5 | EPA 4517517 → |
CK40[C,U]T-49C-**+TDRVery Small HP | 15.5 | EPA 4517527 → |
CK40[C,U]T-49C-**+TDRVery Small HP | 15.5 | EPA 4517528 → |
CK40[C,U]T-49C-**+TDRVery Small HP | 15.5 | EPA 4517529 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →