Lennox / AIR-SOURCE HEAT PUMP

ML14KP1-024-230A**

MERIT ML14KP1 Series · Merit ML14KP1 SERIES · source records, page 5

179 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for ML14KP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 179 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16179 / 179
EER2 · BTU/Wh12–13.8179 / 179
HSPF2 · BTU/Wh7.8–8.2179 / 179
Cooling capacity · BTU/h22,800–24,000179 / 179
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000179 / 179
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700179 / 179
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600179 / 179
COP at 5°F / −15°C1.96–2.2179 / 179
Equipment / loop typeHP - Split System179 / 179
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)179 / 179
Compressor stagingSingle stage179 / 179
Connected capabilityNo179 / 179

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-30B-**+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21571032715.507.80108002.04EPA 3647084
CK40HT-30B-**+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21571032915.508.00111002.06EPA 3647086
CK40HT-30B-**+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21571033115.507.80109002.06EPA 3647088
CK40HT-30B-**+TDR+ furnace: ML296UH070XV36B*AHRI reference: 21571033215.508.00109002.06EPA 3647089
CK40HT-30B-**+TDR+ furnace: SL280UH090V36B*AHRI reference: 21571033415.508.00110002.08EPA 3647091
CK40HT-30B-**+TDR+ furnace: SL280UH090V48B*AHRI reference: 21571033515.508.00109002.06EPA 3647092
CK40HT-30B-**+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21571033715.507.80109002.04EPA 3647094
CK40HT-30B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21571033815.507.80109002.06EPA 3647095
CK40HT-30B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869068115.508.00110002.06EPA 4679278
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869067915.508.00115002.16EPA 4679280
CK40HT-30B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869066115.507.80107002.02EPA 4679289
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869065915.508.00113002.12EPA 4679291
CK40[C,U]T-24B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869065815.507.80107002.00EPA 4679292
CK40[C,U]T-30B-**+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21571022915.208.10115002.14EPA 3646712
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21571023315.207.80114002.12EPA 3646714
CK40[C,U]T-30B-**+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21571023615.207.80115002.12EPA 3646718
CK40[C,U]T-30B-**+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21571023715.208.00113002.12EPA 3646719
CK40HT-24A-**+TDR+ furnace: ML180UH030V36A*AHRI reference: 21571024415.207.80107001.98EPA 3646722
CK40HT-24A-**+TDR+ furnace: ML180UH070E36A*AHRI reference: 21571024815.207.80107001.98EPA 3646724
CK40HT-24A-**+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21571025015.207.80107001.98EPA 3646726