EL21KLV-060-230A**
Elite EL21KLV SERIES · source records, page 5
106 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL21KLV-060-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 106 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–20.5 | 106 / 106 |
| EER2 · BTU/Wh | 11–12.2 | 106 / 106 |
| HSPF2 · BTU/Wh | 8.2–9 | 106 / 106 |
| Cooling capacity · BTU/h | 52,500–56,000 | 106 / 106 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,000–55,500 | 106 / 106 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–46,000 | 106 / 106 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000–38,500 | 106 / 106 |
| COP at 5°F / −15°C | 2.06–2.18 | 106 / 106 |
| Equipment / loop type | HP - Split System | 106 / 106 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 106 / 106 |
| Compressor staging | Continuously variable | 106 / 106 |
| Connected capability | No | 106 / 106 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40[C,U]T-60D-**+TDR+ furnace: ML196UH135XE60D*AHRI reference: 217121524 | 18.50 | 8.50 | 34000 | 2.14 | EPA 4006415 → |
CK40HT-60D-**+TDR+ furnace: ML196UH110XE60C*AHRI reference: 217121505 | 18.50 | 8.50 | 35800 | 2.08 | EPA 4006586 → |
CK40[C,U]T-60D-**+TDR+ furnace: EL297UH135XE60D*AHRI reference: 217121525 | 18.50 | 8.50 | 34600 | 2.12 | EPA 4006591 → |
CBK47UHET-060-230-**AHRI reference: 217121527 | 18.50 | 8.50 | 38000 | 2.16 | EPA 4006593 → |
CK40HT-48C-**+TDR+ furnace: EL280UH110XE60C*AHRI reference: 217443112 | 18.50 | 8.50 | 32800 | 2.16 | EPA 4044490 → |
CK40HT-48C-**+TDR+ furnace: EL280UH110E60C*AHRI reference: 217443111 | 18.50 | 8.50 | 32800 | 2.16 | EPA 4044491 → |
CK40HT-48C-**+TDR+ furnace: ML193UH110XE60C*AHRI reference: 217443116 | 18.50 | 8.50 | 32600 | 2.16 | EPA 4044493 → |
CK40HT-48C-**+TDR+ furnace: ML180UH090E60C*AHRI reference: 217443113 | 18.50 | 8.50 | 32800 | 2.16 | EPA 4044494 → |
CK40HT-51/61C-**+TDR+ furnace: ML196UH090XE60C*AHRI reference: 217465361 | 18.50 | 8.50 | 31400 | 2.06 | EPA 4431405 → |
CK40HT-51/61C-**+TDR+ furnace: EL280UH110E60C*AHRI reference: 217493277 | 18.50 | 8.50 | 31800 | 2.08 | EPA 4433414 → |
CK40HT-51/61C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 217493279 | 18.50 | 8.50 | 31600 | 2.08 | EPA 4433415 → |
CK40HT-51/61C-**+TDR+ furnace: EL280UH110XE60C*AHRI reference: 217493278 | 18.50 | 8.50 | 31800 | 2.08 | EPA 4433417 → |
CK40HT-51/61C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 217493280 | 18.50 | 8.50 | 31600 | 2.08 | EPA 4433418 → |
CK40HT-51/61C-**+TDR+ furnace: ML193UH110XE60C*AHRI reference: 217493281 | 18.50 | 8.50 | 31600 | 2.08 | EPA 4433419 → |
CK40HT-51/61C-**+TDR+ furnace: ML296UH090XV48C*AHRI reference: 217493282 | 18.50 | 8.20 | 31200 | 2.08 | EPA 4433421 → |
CK40HT-51/61C-**+TDR+ furnace: ML296UH110XV60C*AHRI reference: 217493283 | 18.50 | 8.20 | 31000 | 2.10 | EPA 4433423 → |
CBK47UHET-060-460-**AHRI reference: 217595416 | 18.50 | 8.50 | 38000 | 2.16 | EPA 4479673 → |
CK40HT-60D-**+TDR+ furnace: ML180UH135E60D*AHRI reference: 217121499 | 18.00 | 8.50 | 35400 | 2.08 | EPA 4006393 → |
CK40HT-48C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 217443114 | 18.00 | 8.50 | 32600 | 2.16 | EPA 4044492 → |
CK40HT-48C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 217443115 | 18.00 | 8.50 | 32600 | 2.16 | EPA 4044495 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →