EL21KLV-048-230A**
Elite EL21KLV SERIES · source records, page 4
190 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL21KLV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 190 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.7–20.5 | 190 / 190 |
| EER2 · BTU/Wh | 11–13.4 | 190 / 190 |
| HSPF2 · BTU/Wh | 7.8–9.6 | 190 / 190 |
| Cooling capacity · BTU/h | 45,000–48,000 | 190 / 190 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 42,500–52,000 | 190 / 190 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,200–44,500 | 190 / 190 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,000–39,500 | 190 / 190 |
| COP at 5°F / −15°C | 1.88–2.2 | 190 / 190 |
| Equipment / loop type | HP - Split System | 190 / 190 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 190 / 190 |
| Compressor staging | Continuously variable | 190 / 190 |
| Connected capability | No | 190 / 190 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40[C,U]T-60C-**+TDR+ furnace: ML193UH110XE48C*Cold climate designationAHRI reference: 217121974 | 20.00 | 8.50 | 34000 | 2.12 | EPA 4006499 → |
CK40HT-48C-**+TDR+ furnace: SL297UH080NV60C*Cold climate designationAHRI reference: 217117063 | 20.00 | 8.10 | 34000 | 1.96 | EPA 4006542 → |
CK40HT-48C-**+TDR+ furnace: SL280UH080NV48B*Cold climate designationAHRI reference: 217117067 | 20.00 | 8.10 | 34200 | 1.96 | EPA 4006564 → |
CK40HT-48C-**+TDR+ furnace: EL297UH110XV48C*Cold climate designationAHRI reference: 217117070 | 20.00 | 8.10 | 34000 | 1.96 | EPA 4006570 → |
CK40HT-51/61C-**+TDR+ furnace: SL280UH080NV60C*Cold climate designationAHRI reference: 217443383 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044775 → |
CK40HT-51/61C-**+TDR+ furnace: SL280UH090V60C*Cold climate designationAHRI reference: 217443384 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044776 → |
CK40HT-51/61C-**+TDR+ furnace: SL280UH090XV60C*Cold climate designationAHRI reference: 217443385 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044779 → |
CK40HT-51/61C-**+TDR+ furnace: SL280UH110V60C*Cold climate designationAHRI reference: 217443387 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044780 → |
CK40HT-51/61C-**+TDR+ furnace: SL280UH110XV60C*Cold climate designationAHRI reference: 217443388 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044781 → |
CK40HT-51/61C-**+TDR+ furnace: SLP99UH090XV48C*Cold climate designationAHRI reference: 217443393 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044786 → |
CK40HT-51/61C-**+TDR+ furnace: SLP99UH110XV60C*Cold climate designationAHRI reference: 217443396 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044788 → |
CK40HT-51/61C-**+TDR+ furnace: EL297UH090XV48C*Cold climate designationAHRI reference: 217443400 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044793 → |
CK40HT-51/61C-**+TDR+ furnace: EL297UH110XV48C*Cold climate designationAHRI reference: 217443405 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044798 → |
CK40HT-51/61C-**+TDR+ furnace: EL297UH110XV60C*Cold climate designationAHRI reference: 217443406 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044800 → |
CK40[C,U]T-60C-**+TDR+ furnace: ML297UH110XV60C*AHRI reference: 218690728 | 20.00 | 9.00 | 31200 | 2.00 | EPA 4679261 → |
CK40HT-60D-**+TDR+ furnace: ML297UH090XV60C*AHRI reference: 218695160 | 20.00 | 7.80 | 31600 | 1.94 | EPA 4691581 → |
CK40[C,U]T-60D-**+TDR+ furnace: ML297UH090XV60C*AHRI reference: 218695158 | 20.00 | 8.00 | 31000 | 1.88 | EPA 4691583 → |
CK40[C,U]T-60C-**+TDR+ furnace: ML297UH090XV60C*AHRI reference: 218695157 | 20.00 | 8.20 | 31000 | 2.00 | EPA 4691584 → |
CK40HT-60D-**+TDR+ furnace: ML297UH135XV60D*AHRI reference: 218695125 | 20.00 | 8.00 | 31600 | 1.94 | EPA 4691591 → |
CK40[C,U]T-60D-**+TDR+ furnace: ML297UH135XV60D*Cold climate designationAHRI reference: 218695124 | 20.00 | 8.10 | 30800 | 1.88 | EPA 4691592 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →