Lennox / AIR-SOURCE HEAT PUMP

EL21KLV-048-230A**

Elite EL21KLV SERIES

190 published source records · source checked Sep 21, 2026

SEER2 range15.7–20.5BTU/Wh
HSPF2 range7.8–9.6BTU/Wh
Cooling capacity45,000–48,000BTU/h

Each efficiency range summarizes published EPA records for EL21KLV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 190 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.7–20.5190 / 190
EER2 · BTU/Wh11–13.4190 / 190
HSPF2 · BTU/Wh7.8–9.6190 / 190
Cooling capacity · BTU/h45,000–48,000190 / 190
Heating capacity at 47°F / 8.3°C · BTU/h42,500–52,000190 / 190
Heating capacity at 17°F / −8.3°C · BTU/h34,200–44,500190 / 190
Heating capacity at 5°F / −15°C · BTU/h29,000–39,500190 / 190
COP at 5°F / −15°C1.88–2.2190 / 190
Equipment / loop typeHP - Split System190 / 190
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)190 / 190
Compressor stagingContinuously variable190 / 190
Connected capabilityNo190 / 190

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CBK48MVT-060-230-**Cold climate designationAHRI reference: 21711700120.509.00326002.08EPA 4006023
CK40[C,U]T-50/60C-**+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21711707220.508.50294002.16EPA 4006052
CK40HT-60D-**+TDR+ furnace: SL280UH135V60D*AHRI reference: 21711707520.508.50312001.96EPA 4006055
CK40HT-60D-**+TDR+ furnace: SLP99UH135XV60D*AHRI reference: 21711707720.508.50314001.96EPA 4006057
CK40HT-60D-**+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21711708920.508.50314001.96EPA 4006069
CK40HT-60D-**+TDR+ furnace: SL297UH080NV48C*AHRI reference: 21711709020.508.50314001.94EPA 4006070
CK40HT-60D-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21711709220.508.50314001.94EPA 4006072
CK40HT-60D-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21711709320.508.50314001.96EPA 4006073
CK40HT-60D-**+TDR+ furnace: EL297UH135XV60D*AHRI reference: 21711709420.508.50314001.96EPA 4006074
CK40[C,U]T-60C-**+TDR+ furnace: SL280UH080NV60C*Cold climate designationAHRI reference: 21711710720.509.50340002.12EPA 4006084
CK40[C,U]T-60C-**+TDR+ furnace: SL280UH090V60C*Cold climate designationAHRI reference: 21711710820.509.50342002.12EPA 4006085
CK40[C,U]T-60C-**+TDR+ furnace: SL280UH090XV60C*Cold climate designationAHRI reference: 21711710920.509.50342002.12EPA 4006086
CK40[C,U]T-60C-**+TDR+ furnace: SL280UH100NV60C*Cold climate designationAHRI reference: 21711711020.509.50342002.12EPA 4006087
CK40[C,U]T-60C-**+TDR+ furnace: EL297UH110XV48C*Cold climate designationAHRI reference: 21711712020.509.50342002.10EPA 4006097
CK40[C,U]T-60C-**+TDR+ furnace: EL280UH110E48C*Cold climate designationAHRI reference: 21712164320.509.60342002.14EPA 4006482
CK40[C,U]T-60C-**+TDR+ furnace: ML180UH110V60C*Cold climate designationAHRI reference: 21712164820.509.00340002.14EPA 4006487
CK40DT-48C-**+TDR+ furnace: SL280DF090V60C*AHRI reference: 21744339220.508.20320002.06EPA 4044785
CK40DT-48C-**+TDR+ furnace: SL280DF110V60C*AHRI reference: 21744339420.508.20320002.06EPA 4044787
CK40DT-48C-**+TDR+ furnace: SLP99DF090XV60C*AHRI reference: 21744339820.508.20324002.02EPA 4044790
CK40DT-48C-**+TDR+ furnace: SLP99DF090XV48C*AHRI reference: 21744339720.508.20324002.02EPA 4044791