Lennox / AIR-SOURCE HEAT PUMP

EL21KLV-024-230A**

Elite EL21KLV SERIES · source records, page 5

174 published source records · source checked Sep 21, 2026

SEER2 range15.2–21BTU/Wh
HSPF2 range8.1–10.2BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for EL21KLV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 174 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–21174 / 174
EER2 · BTU/Wh11.2–13.5174 / 174
HSPF2 · BTU/Wh8.1–10.2174 / 174
Cooling capacity · BTU/h21,600–24,000174 / 174
Heating capacity at 47°F / 8.3°C · BTU/h23,600–27,400174 / 174
Heating capacity at 17°F / −8.3°C · BTU/h18,700–22,400174 / 174
Heating capacity at 5°F / −15°C · BTU/h13,900–18,600174 / 174
COP at 5°F / −15°C1.7–2.3174 / 174
Equipment / loop typeHP - Split System174 / 174
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)174 / 174
Compressor stagingContinuously variable174 / 174
Connected capabilityNo174 / 174

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH070XE36B*Cold climate designationAHRI reference: 21712155219.009.80174002.10EPA 4006439 →
CK40[C,U]T-30B-**+TDR+ furnace: ML196UH070XE36B*Cold climate designationAHRI reference: 21712155719.009.80177002.10EPA 4006444 →
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21744307119.008.50142001.74EPA 4044452 →
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21744307219.008.50142001.74EPA 4044453 →
CK40[C,U]T-24A-**+TDR+ furnace: EL280UH070E36A*AHRI reference: 21744307419.008.50143001.74EPA 4044455 →
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH030V36A*AHRI reference: 21744307619.008.20141001.74EPA 4044456 →
CK40[C,U]T-24A-**+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21744307519.008.50143001.74EPA 4044457 →
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 21744307719.008.20140001.74EPA 4044458 →
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 21744307919.008.20140001.74EPA 4044461 →
CK40[C,U]T-24B-**+TDR+ furnace: EL280UH090E36B*AHRI reference: 21744308719.008.50143001.74EPA 4044467 →
CK40[C,U]T-24B-**+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21744309119.008.50143001.74EPA 4044471 →
CK40[C,U]T-24B-**+TDR+ furnace: ML180UH090V48B*AHRI reference: 21744309019.008.20142001.74EPA 4044472 →
CK40[C,U]T-24B-**+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21744309319.008.20140001.74EPA 4044475 →
CK40[C,U]T-24B-**+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21744309719.008.50143001.74EPA 4044478 →
CK40[C,U]T-24B-**+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21744310219.008.50143001.74EPA 4044483 →
CK40[C,U]T-24A-**+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21744311919.008.50142001.76EPA 4044496 →
CK40[C,U]T-24B-**+TDR+ furnace: ML180UH070V36B*AHRI reference: 21744312119.008.20140001.76EPA 4044497 →
CK40[C,U]T-24B-**+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21744312319.008.50142001.76EPA 4044498 →
CK40[C,U]T-24B-**+TDR+ furnace: SL280UH090XV48B*AHRI reference: 21744312719.008.50141001.76EPA 4044502 →
CK40[C,U]T-24B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21744312819.008.50142001.76EPA 4044503 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →