Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-048-230A**

Elite EL19KPV SERIES · source records, page 8

218 published source records · source checked Sep 21, 2026

SEER2 range16–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 218 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.5218 / 218
EER2 · BTU/Wh11–11.7218 / 218
HSPF2 · BTU/Wh7.8–9218 / 218
Cooling capacity · BTU/h46,000–48,000218 / 218
Heating capacity at 47°F / 8.3°C · BTU/h45,000–52,000218 / 218
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,200218 / 218
Heating capacity at 5°F / −15°C · BTU/h21,000–32,800218 / 218
COP at 5°F / −15°C1.8–2.26218 / 218
Equipment / loop typeHP - Split System218 / 218
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)218 / 218
Compressor stagingContinuously variable218 / 218
Connected capabilityNo218 / 218

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-49C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21757786117.508.50234001.90EPA 4480412 →
CK40[C,U]T-60C-**+TDR+ furnace: EL180UH100NE60C*AHRI reference: 21757787017.508.50238001.94EPA 4480417 →
CK40[C,U]T-60C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 21757787617.508.50236001.98EPA 4480424 →
CK40[C,U]T-60C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21757787917.508.50230001.94EPA 4480425 →
CK40[C,U]T-60C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21757787817.508.50236001.98EPA 4480429 →
CBK47UHET-060-460-**AHRI reference: 21759542417.509.00328002.24EPA 4480468 →
CK40HT-51/61C-**+TDR+ furnace: ML297UH110XV60C*AHRI reference: 21869072117.508.10292001.88EPA 4679263 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML297UH110XV60C*AHRI reference: 21869071917.508.00248001.94EPA 4679264 →
CK40[C,U]T-49C-**+TDR+ furnace: ML297UH110XV60C*AHRI reference: 21869071817.508.50246001.94EPA 4679265 →
CK40DT-48C-**+TDR+ furnace: ML297DF110XV60C*AHRI reference: 21869065517.508.10260001.96EPA 4679293 →
CK40[C,U]T-49C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874773117.509.00244001.96EPA 4705674 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21719451417.007.80220001.82EPA 4011446 →
CBK45UHVT-060-230-**AHRI reference: 21719464917.008.10214001.96EPA 4011454 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21719443317.008.10238001.82EPA 4011523 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21719443417.008.20234001.88EPA 4011524 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML180UH090E60C*AHRI reference: 21719443817.008.20232001.88EPA 4011528 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21719444717.008.20234001.86EPA 4011537 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21719444817.008.00238001.86EPA 4011538 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21719446317.008.20234001.86EPA 4011553 →
CK40[C,U]T-48C-**+TDR+ furnace: EL195UH080NE48C*AHRI reference: 21719447117.007.80220001.80EPA 4011561 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →