Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-048-230A**

Elite EL19KPV SERIES · source records, page 6

218 published source records · source checked Sep 21, 2026

SEER2 range16–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 218 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.5218 / 218
EER2 · BTU/Wh11–11.7218 / 218
HSPF2 · BTU/Wh7.8–9218 / 218
Cooling capacity · BTU/h46,000–48,000218 / 218
Heating capacity at 47°F / 8.3°C · BTU/h45,000–52,000218 / 218
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,200218 / 218
Heating capacity at 5°F / −15°C · BTU/h21,000–32,800218 / 218
COP at 5°F / −15°C1.8–2.26218 / 218
Equipment / loop typeHP - Split System218 / 218
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)218 / 218
Compressor stagingContinuously variable218 / 218
Connected capabilityNo218 / 218

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40DT-60D-**+TDR+ furnace: ML297DF110XV60C*AHRI reference: 21869511518.008.20302001.88EPA 4691597 →
CK40HT-48C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874772918.007.80238001.80EPA 4705676 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874772818.008.20244001.96EPA 4705677 →
CK40[C,U]T-48C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874772718.007.80228001.86EPA 4705678 →
CK40HT-48C-**+TDR+ furnace: ML180UH090E60C*AHRI reference: 21719450817.507.80238001.80EPA 4011443 →
CK40HT-48C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 21719450917.507.80236001.80EPA 4011444 →
CK40HT-48C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21719451317.507.80236001.80EPA 4011445 →
CBK45UHET-060-230-**AHRI reference: 21719465217.508.20210001.98EPA 4011455 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL180UH100NE60C*AHRI reference: 21719443217.508.20238001.84EPA 4011522 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL280UH110E60C*AHRI reference: 21719443617.508.20234001.88EPA 4011525 →
CK40[C,U]T-50/60C-**+TDR+ furnace: EL280UH110XE60C*AHRI reference: 21719443717.508.20234001.88EPA 4011527 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21719444317.508.20234001.88EPA 4011533 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21719444417.508.20236001.86EPA 4011534 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21719444617.508.20236001.86EPA 4011536 →
CK40[C,U]T-50/60C-**+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21719444917.508.00236001.88EPA 4011539 →
CK40[C,U]T-48C-**+TDR+ furnace: EL180UH100NE60C*AHRI reference: 21719447017.507.80224001.80EPA 4011560 →
CK40DT-60D-**+TDR+ furnace: EL297DF110XE60C*AHRI reference: 21744682917.508.50298001.92EPA 4045427 →
CK40HT-51/61C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 21744679317.508.20290001.90EPA 4045559 →
CK40HT-51/61C-**+TDR+ furnace: ML180UH110V60C*AHRI reference: 21744679417.508.20288001.92EPA 4045560 →
CK40HT-51/61C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21744679517.508.20290001.90EPA 4045561 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →