Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-048-230A**

Elite EL19KPV SERIES · source records, page 3

218 published source records · source checked Sep 21, 2026

SEER2 range16–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 218 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.5218 / 218
EER2 · BTU/Wh11–11.7218 / 218
HSPF2 · BTU/Wh7.8–9218 / 218
Cooling capacity · BTU/h46,000–48,000218 / 218
Heating capacity at 47°F / 8.3°C · BTU/h45,000–52,000218 / 218
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,200218 / 218
Heating capacity at 5°F / −15°C · BTU/h21,000–32,800218 / 218
COP at 5°F / −15°C1.8–2.26218 / 218
Equipment / loop typeHP - Split System218 / 218
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)218 / 218
Compressor stagingContinuously variable218 / 218
Connected capabilityNo218 / 218

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-50/60C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21719444518.008.20234001.86EPA 4011535
CK40[C,U]T-50/60C-**+TDR+ furnace: SL280UH090V60C*AHRI reference: 21719445118.008.20236001.86EPA 4011541
CK40[C,U]T-50/60C-**+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21719445218.008.20236001.86EPA 4011542
CK40[C,U]T-50/60C-**+TDR+ furnace: SL280UH110V60C*AHRI reference: 21719445418.008.20236001.88EPA 4011544
CK40[C,U]T-50/60C-**+TDR+ furnace: SL280UH110XV60C*AHRI reference: 21719445518.008.20236001.88EPA 4011545
CK40[C,U]T-50/60C-**+TDR+ furnace: SL297UH080NV60C*AHRI reference: 21719445718.008.20240001.84EPA 4011547
CK40[C,U]T-50/60C-**+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21719445818.008.20238001.84EPA 4011548
CK40[C,U]T-50/60C-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21719445918.008.20238001.86EPA 4011549
CK40[C,U]T-50/60C-**+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21719446018.008.20238001.86EPA 4011550
CK40[C,U]T-50/60C-**+TDR+ furnace: EL297UH090XV48C*AHRI reference: 21719446118.008.20238001.84EPA 4011551
CK40[C,U]T-50/60C-**+TDR+ furnace: EL297UH090XV60C*AHRI reference: 21719446218.008.20238001.86EPA 4011552
CK40[C,U]T-50/60C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21719446518.008.20238001.86EPA 4011555
CK40[C,U]T-48C-**+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21719447318.007.80220001.80EPA 4011563
CK40[C,U]T-48C-**+TDR+ furnace: EL280UH110E48C*AHRI reference: 21719447518.007.80220001.82EPA 4011565
CK40[C,U]T-48C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 21719447918.007.80222001.82EPA 4011569
CK40[C,U]T-48C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21719448118.007.80222001.82EPA 4011570
CK40[C,U]T-48C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21719448218.007.80220001.80EPA 4011571
CK40[C,U]T-48C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21719448318.007.80220001.82EPA 4011572
CK40[C,U]T-48C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21719448518.007.80220001.82EPA 4011574
CK40HT-48C-**+TDR+ furnace: EL280UH110E48C*AHRI reference: 21719450318.007.80234001.80EPA 4011578

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →