Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-048-230A**

Elite EL19KPV SERIES · source records, page 10

218 published source records · source checked Sep 21, 2026

SEER2 range16–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-048-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 218 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.5218 / 218
EER2 · BTU/Wh11–11.7218 / 218
HSPF2 · BTU/Wh7.8–9218 / 218
Cooling capacity · BTU/h46,000–48,000218 / 218
Heating capacity at 47°F / 8.3°C · BTU/h45,000–52,000218 / 218
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,200218 / 218
Heating capacity at 5°F / −15°C · BTU/h21,000–32,800218 / 218
COP at 5°F / −15°C1.8–2.26218 / 218
Equipment / loop typeHP - Split System218 / 218
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)218 / 218
Compressor stagingContinuously variable218 / 218
Connected capabilityNo218 / 218

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-51/61C-**+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21744680717.008.20290001.92EPA 4045573 →
CK40HT-51/61C-**+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21744681217.008.20290001.90EPA 4045578 →
CK40HT-51/61C-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21744681317.008.20290001.90EPA 4045579 →
CK40HT-51/61C-**+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21744681417.008.20290001.92EPA 4045580 →
CK40HT-51/61C-**+TDR+ furnace: EL297UH090XV48C*AHRI reference: 21744681517.008.20292001.90EPA 4045581 →
CK40HT-51/61C-**+TDR+ furnace: EL297UH090XV60C*AHRI reference: 21744681617.008.20290001.90EPA 4045582 →
CK40HT-51/61C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21744681717.008.20290001.90EPA 4045583 →
CK40HT-51/61C-**+TDR+ furnace: EL297UH110XV48C*AHRI reference: 21744681817.008.20290001.90EPA 4045584 →
CK40HT-51/61C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21744681917.008.20290001.92EPA 4045585 →
CK40DT-48C-**+TDR+ furnace: ML196DF110XE60C*AHRI reference: 21750760317.008.20244001.92EPA 4469636 →
CK40DT-48C-**+TDR+ furnace: ML296DF090XV60C*AHRI reference: 21750760417.008.00248001.88EPA 4469637 →
CK40[C,U]T-49C-**+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21757781917.008.50234001.92EPA 4480374 →
CK40[C,U]T-49C-**+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21757782117.008.50234001.92EPA 4480375 →
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21757783217.008.50234001.92EPA 4480381 →
CK40[C,U]T-60C-**+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21757783617.008.50230001.96EPA 4480386 →
CK40[C,U]T-60C-**+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21757783817.008.50230001.96EPA 4480388 →
CK40[C,U]T-60C-**+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21757783917.008.50238001.96EPA 4480390 →
CK40[C,U]T-60C-**+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21757783717.008.50236001.96EPA 4480391 →
CK40[C,U]T-60C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21757784917.008.50230001.96EPA 4480398 →
CK40[C,U]T-49C-**+TDR+ furnace: ML180UH090E60C*AHRI reference: 21757785717.008.50232001.92EPA 4480404 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.