Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-036-230A**

Elite EL19KPV SERIES · source records, page 2

154 published source records · source checked Sep 21, 2026

SEER2 range15.5–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,200–35,800BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 154 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19154 / 154
EER2 · BTU/Wh11–11.5154 / 154
HSPF2 · BTU/Wh7.8–8.5154 / 154
Cooling capacity · BTU/h33,200–35,800154 / 154
Heating capacity at 47°F / 8.3°C · BTU/h31,000–36,000154 / 154
Heating capacity at 17°F / −8.3°C · BTU/h18,400–23,000154 / 154
Heating capacity at 5°F / −15°C · BTU/h14,600–17,700154 / 154
COP at 5°F / −15°C1.9–2.3154 / 154
Equipment / loop typeHP - Split System154 / 154
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)154 / 154
Compressor stagingContinuously variable154 / 154
Connected capabilityNo154 / 154

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CBK48MVT-036-230-**AHRI reference: 21719418318.008.40177002.20EPA 4011423
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21719418418.008.20151001.92EPA 4011424
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH090V36B*AHRI reference: 21719418518.008.20149001.92EPA 4011425
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH090V48B*AHRI reference: 21719418618.008.20150001.92EPA 4011426
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH090XV48B*AHRI reference: 21719418718.008.20150001.92EPA 4011428
CK40[C,U]T-36B-**+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21719419218.008.20151001.90EPA 4011429
CK40[C,U]T-36B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21719419018.008.20150001.92EPA 4011430
CK40[C,U]T-36B-**+TDR+ furnace: EL195UH040NE36B*AHRI reference: 21719419818.008.20149001.90EPA 4011433
CK40[C,U]T-36B-**+TDR+ furnace: EL195UH060NE36B*AHRI reference: 21719419918.008.20148001.92EPA 4011434
CK40[C,U]T-36B-**+TDR+ furnace: EL196UH070XE36B*AHRI reference: 21719420118.008.20150001.92EPA 4011435
CK40[C,U]T-36B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 21719420518.008.20149001.92EPA 4011439
CK40[C,U]T-36B-**+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21719420818.008.20149001.92EPA 4011459
CK40[C,U]T-36B-**+TDR+ furnace: ML180UH090V48B*AHRI reference: 21719421018.008.20150001.92EPA 4011461
CK40[C,U]T-36B-**+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21719421318.008.20149001.92EPA 4011463
CK40[C,U]T-36B-**+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21719421618.008.20150001.92EPA 4011465
CK40[C,U]T-36B-**+TDR+ furnace: EL297UH070XE36B*AHRI reference: 21719422018.008.20150001.90EPA 4011468
CK40[C,U]T-36B-**+TDR+ furnace: EL297UH045XE36B*AHRI reference: 21719422118.008.20148001.92EPA 4011469
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH030V36A*AHRI reference: 21719422718.008.10150001.92EPA 4011475
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 21719422918.008.10150001.92EPA 4011477
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH070E36A*AHRI reference: 21719423118.008.20150001.90EPA 4011479

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →