Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-024-230A**

Elite EL19KPV SERIES · source records, page 2

221 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 221 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20221 / 221
EER2 · BTU/Wh11–13.4221 / 221
HSPF2 · BTU/Wh7.8–9221 / 221
Cooling capacity · BTU/h21,600–24,000221 / 221
Heating capacity at 47°F / 8.3°C · BTU/h22,800–25,600221 / 221
Heating capacity at 17°F / −8.3°C · BTU/h13,300–17,000221 / 221
Heating capacity at 5°F / −15°C · BTU/h11,700–17,000221 / 221
COP at 5°F / −15°C1.48–2.04221 / 221
Equipment / loop typeHP - Split System221 / 221
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)221 / 221
Compressor stagingContinuously variable221 / 221
Connected capabilityNo221 / 221

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21744687219.508.50165002.02EPA 4045470
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21744687319.508.50165002.02EPA 4045471
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 21744688219.508.50163002.02EPA 4045480
CK40[C,U]T-30B-**+TDR+ furnace: EL196UH030XE36B*AHRI reference: 21744688919.508.10138001.86EPA 4045487
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH070V36B*AHRI reference: 21744689619.508.20138001.90EPA 4045494
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH070V48B*AHRI reference: 21744689719.508.00139001.90EPA 4045495
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH090V48B*AHRI reference: 21744689919.508.10140001.88EPA 4045497
CK40[C,U]T-30B-**+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21744690019.508.10137001.86EPA 4045498
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH090V36B*AHRI reference: 21744691819.508.20138001.88EPA 4045516
CK40[C,U]T-30B-**+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21744692319.508.10139001.86EPA 4045521
CK40[C,U]T-30B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21744692619.508.20138001.88EPA 4045524
CK40[C,U]T-30B-**+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21744694119.508.10138001.88EPA 4045616
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH030V36A*AHRI reference: 21744695719.508.10139001.88EPA 4045633
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 21744696219.508.10138001.88EPA 4045638
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 21744696719.508.10138001.88EPA 4045642
CK40[C,U]T-30A-**+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21744696919.508.10138001.88EPA 4045644
CBK45UHET-030-230-**AHRI reference: 21744698019.508.50158001.88EPA 4045655
CK40DT-42B-**+TDR+ furnace: EL297DF070XV48B*AHRI reference: 21750761619.509.00146002.02EPA 4469649
CK40[C,U]T-36C-**+TDR+ furnace: ML297UH090XV36C*AHRI reference: 21869510019.507.80118001.72EPA 4691604
CK40[C,U]T-36B-**+TDR+ furnace: EL196UH030XE36B*AHRI reference: 21719413419.008.50150001.86EPA 4011060

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →