| SEER2 · BTU/Wh | 15.2–19.3 | 355 / 355 |
| EER2 · BTU/Wh | 10–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 355 / 355 |
| Cooling capacity · BTU/h | 32,200–36,200 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 355 / 355 |
| COP at 5°F / −15°C | 1.8–1.95 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-36B-**+TDR+ furnace: SL280UH090V36B*Cold climate designationAHRI reference: 217449901 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4045818 → |
CK40HT-36B-**+TDR+ furnace: ML180UH070V36B*Cold climate designationAHRI reference: 217449903 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4045820 → |
CK40HT-30B-**+TDR+ furnace: ML193UH030XE36B*Cold climate designationAHRI reference: 217449885 | 18.00 | 8.50 | 28600 | 1.85 | EPA 4045859 → |
CK40HT-30B-**+TDR+ furnace: ML180UH070V36B*Cold climate designationAHRI reference: 217449878 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4046162 → |
CBK48MVT-030-230-**Cold climate designationAHRI reference: 217753035 | 18.00 | 9.50 | 29600 | 1.90 | EPA 4511941 → |
CK40[C,U]T-36C-**+TDR+ furnace: SLP99UH090XV36C*Cold climate designationAHRI reference: 218082933 | 18.00 | 8.50 | 28200 | 1.85 | EPA 4569973 → |
CK40[C,U]T-36C-**+TDR+ furnace: SL297UH080NV60C*Cold climate designationAHRI reference: 218082932 | 18.00 | 8.50 | 28400 | 1.85 | EPA 4569974 → |
CK40HT-36C-**+TDR+ furnace: ML297UH090XV36C*Cold climate designationAHRI reference: 218730764 | 18.00 | 9.00 | 28400 | 1.90 | EPA 4695851 → |
CK40HT-30B-**+TDR+ furnace: ML180UH070E36B*Cold climate designationAHRI reference: 217189839 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007885 → |
CK40HT-30B-**+TDR+ furnace: ML180UH070XE36B*Cold climate designationAHRI reference: 217189840 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007886 → |
CK40HT-36B-**+TDR+ furnace: ML180UH070XE36B*Cold climate designationAHRI reference: 217189863 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4007957 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL180UH040NE36A*Cold climate designationAHRI reference: 217189808 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4008014 → |
CK40HT-30A-**+TDR+ furnace: EL180UH040NE36A*Cold climate designationAHRI reference: 217189831 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4008078 → |
CK40HT-30A-**+TDR+ furnace: EL180UH060NE36A*Cold climate designationAHRI reference: 217189832 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4008079 → |
CK40HT-30A-**+TDR+ furnace: ML180UH070E36A*Cold climate designationAHRI reference: 217189836 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4008082 → |
CK40HT-36B-**+TDR+ furnace: ML180UH070E36B*Cold climate designationAHRI reference: 217189862 | 17.95 | 8.50 | 28400 | 1.85 | EPA 4008107 → |
CK40HT-36C-**+TDR+ furnace: SLP99UH090XV48C*Cold climate designationAHRI reference: 217189876 | 17.95 | 9.00 | 28400 | 1.90 | EPA 4008113 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML180UH070V48B*Cold climate designationAHRI reference: 217449843 | 17.95 | 8.10 | 29200 | 1.80 | EPA 4045838 → |
CK40HT-30A-**+TDR+ furnace: ML180UH070XE36A*Cold climate designationAHRI reference: 217449872 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4045891 → |
CK40DT-42B-**+TDR+ furnace: ML193DF070XE36B*Cold climate designationAHRI reference: 217449944 | 17.95 | 9.00 | 28200 | 1.90 | EPA 4045990 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.