EL18KSLV-036-230A**
EL18KSLV SERIES · EL18KSLV Series · Elite EL18KSLV Series · source records, page 15
355 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL18KSLV-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 355 / 355 |
| EER2 · BTU/Wh | 10–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 355 / 355 |
| Cooling capacity · BTU/h | 32,200–36,200 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 355 / 355 |
| COP at 5°F / −15°C | 1.8–1.95 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-30B-**+TDR+ furnace: ML180UH090XE48B*Cold climate designationAHRI reference: 217449892 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4045981 → |
CK40HT-36A-**+TDR+ furnace: ML180UH070XE36A*Cold climate designationAHRI reference: 217449897 | 16.95 | 8.50 | 28800 | 1.80 | EPA 4045985 → |
CK40DT-42B-**+TDR+ furnace: ML296DF045XV36B*Cold climate designationAHRI reference: 217449945 | 16.95 | 8.50 | 28400 | 1.90 | EPA 4045991 → |
CK40DT-30/36B-**+TDR+ furnace: SL280DF090V48B*Cold climate designationAHRI reference: 217509777 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4438960 → |
CK40[C,U]T-30/36C**+TDR+ furnace: ML193UH090XE48C*Cold climate designationAHRI reference: 217677944 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4498283 → |
CK40DT-30/36B-***+TDR+ furnace: SL280DF090V48B*Cold climate designationAHRI reference: 218114523 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4573252 → |
CK40DT-30/36B-***+TDR+ furnace: ML193DF045XE36B*Cold climate designationAHRI reference: 218114520 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4573255 → |
CK40DT-30/36B-***+TDR+ furnace: ML196DF070XE48B*Cold climate designationAHRI reference: 218114516 | 16.95 | 8.50 | 28800 | 1.85 | EPA 4573259 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML180DF090E48B*Cold climate designationAHRI reference: 217189805 | 16.90 | 8.50 | 28400 | 1.85 | EPA 4007900 → |
CK40HT-36B-**+TDR+ furnace: ML180UH090E48B*Cold climate designationAHRI reference: 217189873 | 16.90 | 8.50 | 28200 | 1.85 | EPA 4008110 → |
CK40HT-36B-**+TDR+ furnace: ML180UH090XE48B*Cold climate designationAHRI reference: 217449917 | 16.90 | 8.50 | 28200 | 1.85 | EPA 4045840 → |
CK40HT-30B-**+TDR+ furnace: ML296UH045XV36B*Cold climate designationAHRI reference: 217449888 | 16.90 | 8.50 | 28600 | 1.85 | EPA 4045861 → |
CK40HT-36B-**+TDR+ furnace: ML296UH070XV36B*Cold climate designationAHRI reference: 217449914 | 16.90 | 8.50 | 28600 | 1.85 | EPA 4046008 → |
CK40[C,U]T-30/36C**+TDR+ furnace: EL196UH090XE48C*Cold climate designationAHRI reference: 217677940 | 16.90 | 8.50 | 28600 | 1.85 | EPA 4498274 → |
CK40[C,U]T-30/36C**+TDR+ furnace: EL297UH090XE48C*Cold climate designationAHRI reference: 217677942 | 16.90 | 8.50 | 28400 | 1.85 | EPA 4498276 → |
CK40DT-30/36B-**+TDR+ furnace: SLP99DF070XV36B*Cold climate designationAHRI reference: 217189880 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4007856 → |
CK40HT-36B-**+TDR+ furnace: EL196UH030XE36B*Cold climate designationAHRI reference: 217449906 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4045823 → |
CK40HT-36B-**+TDR+ furnace: ML296UH045XV36B*Cold climate designationAHRI reference: 217449913 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4046007 → |
CK40HT-30B-**+TDR+ furnace: EL196UH030XE36B*Cold climate designationAHRI reference: 217449881 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4046173 → |
CK40DT-30/36B-***+TDR+ furnace: SLP99DF070XV36B*Cold climate designationAHRI reference: 218114513 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4573262 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →