EL18KSLV-036-230A**
EL18KSLV SERIES · EL18KSLV Series · Elite EL18KSLV Series
355 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL18KSLV-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 355 / 355 |
| EER2 · BTU/Wh | 10–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 355 / 355 |
| Cooling capacity · BTU/h | 32,200–36,200 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 355 / 355 |
| COP at 5°F / −15°C | 1.8–1.95 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-42B-**+TDR+ furnace: EL297UH070XV36B*Cold climate designationAHRI reference: 218672219 | 19.30 | 9.10 | 27600 | 1.90 | EPA 4670908 → |
CBK48MVT-042-230-**Cold climate designationAHRI reference: 216618914 | 19.00 | 9.40 | 29400 | 1.95 | EPA 3893224 → |
CK40HT-36C-**+TDR+ furnace: ML196UH090XE36C*Cold climate designationAHRI reference: 217449921 | 18.85 | 9.00 | 28400 | 1.90 | EPA 4045844 → |
CK40[C,U]T-36C-**+TDR+ furnace: ML180UH110V60C*Cold climate designationAHRI reference: 218082917 | 18.80 | 8.50 | 28200 | 1.90 | EPA 4569989 → |
CK40HT-36C-**+TDR+ furnace: ML193UH090XE36C*Cold climate designationAHRI reference: 217449922 | 18.70 | 9.00 | 28200 | 1.90 | EPA 4045845 → |
CK40[C,U]T-36B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449852 | 18.65 | 8.50 | 28200 | 1.85 | EPA 4045724 → |
CK40HT-30A-**+TDR+ furnace: EL280UH045E36A*Cold climate designationAHRI reference: 217189835 | 18.60 | 9.00 | 28400 | 1.90 | EPA 4008315 → |
CK40HT-36B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449902 | 18.60 | 8.50 | 28400 | 1.85 | EPA 4045819 → |
CK40HT-36C-**+TDR+ furnace: ML296UH090XV48C*Cold climate designationAHRI reference: 217449930 | 18.55 | 9.00 | 28200 | 1.90 | EPA 4045979 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449877 | 18.55 | 8.50 | 28400 | 1.85 | EPA 4046668 → |
CK40[C,U]T-36C-**+TDR+ furnace: ML296UH110XV60C*Cold climate designationAHRI reference: 218082924 | 18.55 | 8.50 | 28400 | 1.85 | EPA 4569982 → |
CK40[C,U]T-36C-**+TDR+ furnace: ML196UH090XE36C*Cold climate designationAHRI reference: 218082922 | 18.55 | 8.50 | 28200 | 1.85 | EPA 4569984 → |
CBK48MVT-036-230-**Cold climate designationAHRI reference: 216618913 | 18.50 | 9.40 | 29400 | 1.90 | EPA 3893064 → |
CBK45UHET-036-230-**Cold climate designationAHRI reference: 216618909 | 18.50 | 9.00 | 30000 | 1.90 | EPA 3893223 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL280UH045E36A*Cold climate designationAHRI reference: 217189812 | 18.50 | 8.50 | 28600 | 1.85 | EPA 4008018 → |
CBK47UHET-036-230-**Cold climate designationAHRI reference: 216705371 | 18.50 | 9.40 | 29400 | 1.90 | EPA 4028700 → |
CK40[C,U]T-30/36C**+TDR+ furnace: ML196UH090XE36C*Cold climate designationAHRI reference: 217677937 | 18.45 | 8.50 | 28600 | 1.85 | EPA 4498271 → |
CK40HT-36C-**+TDR+ furnace: EL297UH090XV48C*Cold climate designationAHRI reference: 217449926 | 18.40 | 9.00 | 28200 | 1.90 | EPA 4045976 → |
CK40[C,U]T-36C-**+TDR+ furnace: SL280UH090XV60C*Cold climate designationAHRI reference: 218082927 | 18.40 | 8.50 | 28200 | 1.90 | EPA 4569979 → |
CK40[C,U]T-36C-**+TDR+ furnace: SL280UH090V60C*Cold climate designationAHRI reference: 218082926 | 18.40 | 8.50 | 28200 | 1.90 | EPA 4569980 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →