EL18KSLV-024-230A**
EL18KSLV SERIES · EL18KSLV Series · Elite EL18KSLV Series · source records, page 5
205 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL18KSLV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 205 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 205 / 205 |
| EER2 · BTU/Wh | 11–12.3 | 205 / 205 |
| HSPF2 · BTU/Wh | 8.5–10 | 205 / 205 |
| Cooling capacity · BTU/h | 23,200–24,200 | 205 / 205 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 205 / 205 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 205 / 205 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 205 / 205 |
| COP at 5°F / −15°C | 1.75–1.85 | 205 / 205 |
| Equipment / loop type | HP - Split System | 205 / 205 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 205 / 205 |
| Compressor staging | Continuously variable | 205 / 205 |
| Connected capability | No | 205 / 205 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40HT-30A-**+TDR+ furnace: EL280UH070XE36A*Cold climate designationAHRI reference: 217189765 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4007908 → |
CK40HT-30A-**+TDR+ furnace: EL280UH070E36A*Cold climate designationAHRI reference: 217189766 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4007909 → |
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045E36A*Cold climate designationAHRI reference: 217189735 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4007942 → |
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045XE36A*Cold climate designationAHRI reference: 217189736 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4007943 → |
CK40DT-24B-**+TDR+ furnace: SLP99DF070XV36B*Cold climate designationAHRI reference: 217189781 | 17.15 | 9.40 | 20800 | 1.80 | EPA 4008062 → |
CK40HT-24B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449782 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4045710 → |
CK40[C,U]T-36B-**+TDR+ furnace: ML193UH045XE36B*Cold climate designationAHRI reference: 217449767 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4045792 → |
CK40[C,U]T-36B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449758 | 17.15 | 9.00 | 20400 | 1.85 | EPA 4045852 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E36B*Cold climate designationAHRI reference: 217449801 | 17.15 | 9.00 | 20600 | 1.80 | EPA 4045972 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH070XV36B*Cold climate designationAHRI reference: 218730749 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4696880 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL280UH070XE36A*Cold climate designationAHRI reference: 217189731 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4007930 → |
CK40[C,U]T-36A-**+TDR+ furnace: EL280UH070E36A*Cold climate designationAHRI reference: 217189732 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4007931 → |
CK40HT-24B-**+TDR+ furnace: EL196UH030XE36B*Cold climate designationAHRI reference: 217449786 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4045713 → |
CK40HT-24B-**+TDR+ furnace: ML196UH030XE36B*Cold climate designationAHRI reference: 217449789 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4045742 → |
CK40HT-30B-**+TDR+ furnace: ML193UH030XE36B*Cold climate designationAHRI reference: 217449809 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4045762 → |
CK40HT-30B-**+TDR+ furnace: ML193UH045XE36B*Cold climate designationAHRI reference: 217449810 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4045763 → |
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH070V36A*Cold climate designationAHRI reference: 217449737 | 17.10 | 9.00 | 20800 | 1.80 | EPA 4045776 → |
CK40[C,U]T-30A-**+TDR+ furnace: EL180UH060NE36A*Cold climate designationAHRI reference: 217189713 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4007865 → |
CK40[C,U]T-36A-**+TDR+ furnace: SL280UH070V36A*Cold climate designationAHRI reference: 217189727 | 17.05 | 9.00 | 20800 | 1.85 | EPA 4007925 → |
CK40[C,U]T-30A-**+TDR+ furnace: EL180UH040NE36A*Cold climate designationAHRI reference: 217189712 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4008302 → |