EL18KSLV-024-230A**
EL18KSLV SERIES · EL18KSLV Series · Elite EL18KSLV Series · source records, page 10
205 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL18KSLV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 205 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 205 / 205 |
| EER2 · BTU/Wh | 11–12.3 | 205 / 205 |
| HSPF2 · BTU/Wh | 8.5–10 | 205 / 205 |
| Cooling capacity · BTU/h | 23,200–24,200 | 205 / 205 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 205 / 205 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 205 / 205 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 205 / 205 |
| COP at 5°F / −15°C | 1.75–1.85 | 205 / 205 |
| Equipment / loop type | HP - Split System | 205 / 205 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 205 / 205 |
| Compressor staging | Continuously variable | 205 / 205 |
| Connected capability | No | 205 / 205 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40[C,U]T-30B-**+TDR+ furnace: EL195UH060NE36B*Cold climate designationAHRI reference: 217189724 | 16.25 | 9.00 | 21000 | 1.80 | EPA 4007882 → |
CK40HT-24A-**+TDR+ furnace: ML180UH070E36A*Cold climate designationAHRI reference: 217189751 | 16.20 | 8.50 | 21200 | 1.80 | EPA 4008312 → |
CK40[C,U]T-30B-**+TDR+ furnace: EL196UH070XE36B*Cold climate designationAHRI reference: 217449742 | 16.20 | 9.00 | 21000 | 1.80 | EPA 4045781 → |
CK40HT-24A-**+TDR+ furnace: ML180UH070XE36A*Cold climate designationAHRI reference: 217449777 | 16.20 | 8.50 | 21200 | 1.80 | EPA 4045964 → |
CK40DT-24B-**+TDR+ furnace: ML296DF045XV36B*Cold climate designationAHRI reference: 217449820 | 16.15 | 9.00 | 21200 | 1.80 | EPA 4045765 → |
CK40[C,U]T-30B-**+TDR+ furnace: EL297UH070XE36B*Cold climate designationAHRI reference: 217449745 | 16.15 | 9.00 | 21000 | 1.80 | EPA 4045783 → |
CK40[C,U]T-30B-**+TDR+ furnace: EL195UH040NE36B*Cold climate designationAHRI reference: 217189723 | 16.10 | 8.50 | 21000 | 1.80 | EPA 4007881 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML196UH070XE36B*Cold climate designationAHRI reference: 217189726 | 16.10 | 9.00 | 20800 | 1.80 | EPA 4007884 → |
CK40DT-24B-**+TDR+ furnace: ML180DF070E36B*Cold climate designationAHRI reference: 217189780 | 16.10 | 9.00 | 21000 | 1.80 | EPA 4008061 → |
CK40[C,U]T-30B-**+TDR+ furnace: ML196UH045XE36B*Cold climate designationAHRI reference: 217189725 | 16.05 | 8.50 | 21000 | 1.80 | EPA 4007883 → |
CK40[C,U]T-30B-**+TDR+ furnace: EL196UH045XE36B*Cold climate designationAHRI reference: 217449741 | 16.05 | 8.50 | 21000 | 1.80 | EPA 4045780 → |
CK40HT-30A-**+TDRCold climate designationAHRI reference: 216618929 | 16.00 | 9.00 | 22600 | 1.80 | EPA 3893101 → |
CK40DT-24B-**+TDR+ furnace: EL297DF045XE36B*Cold climate designationAHRI reference: 217449816 | 16.00 | 9.00 | 21000 | 1.80 | EPA 4045951 → |
CK40DT-24A-**+TDR+ furnace: ML180DF070E36A*Cold climate designationAHRI reference: 217189984 | 15.90 | 9.00 | 21200 | 1.80 | EPA 4007848 → |
CK40[C,U]T-24B-**+TDRCold climate designationAHRI reference: 216581392 | 15.80 | 8.50 | 20000 | 1.75 | EPA 3848850 → |
CBK45UHPT-018-230-**Cold climate designationAHRI reference: 216618900 | 15.20 | 9.00 | 23200 | 1.75 | EPA 3893059 → |
CK40[C,U]T-30A-**+TDRCold climate designationAHRI reference: 216618922 | 15.20 | 8.50 | 21400 | 1.75 | EPA 3893080 → |
CK40[C,U]T-30B-**+TDRCold climate designationAHRI reference: 216618923 | 15.20 | 8.50 | 21400 | 1.75 | EPA 3893081 → |
CK40[C,U]T-36A-**+TDRCold climate designationAHRI reference: 216618924 | 15.20 | 8.50 | 21000 | 1.80 | EPA 3893082 → |
CK40[C,U]T-36B-**+TDRCold climate designationAHRI reference: 216618925 | 15.20 | 8.50 | 21000 | 1.80 | EPA 3893098 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →